4 | Operating the system
26
B1300122_en | Operating instructions Lambdamat LM 800-1000
Before working in the fuel
store
r
Switch off the boiler by tapping “Boiler off” at the mode icon and switch off main switch
r
Turn off the main switch on the expansion switch cabinet (if installed)
r
Distribute any fuel remaining in the store (in corners, against walls) over the head of
the rotary agitator with your hands
Ä
Follow the instructions on working in the fuel store!
NOTICE! Refer to the notice at the entrance to the fuel store
After working in the fuel
store
r
Turn on the main switch on the boiler and on the expansion switch cabinet (if installed)
For combined drive:
r
Activate “Extra heating” mode in the quick selection menu
For separate drive:
r
Tap “On” in “Bunker filling rotary agitator” during manual operation
Ä
The rotary agitator head runs for approx. 3 minutes
r
Wait until the rotary agitator arms / spring blades are touching the head of the rotary
agitator (approx. 2 revolutions)
r
Switch off the boiler by tapping “Boiler off” at the mode icon and allow to cool for at
least two hours
r
Close all openings to the store to seal out dust
r
Blow the fuel into the fuel store
If the fuel store is completely empty and there is no residual fuel to redistribute:
r
Contact Froling and seek advice before filling the fuel store
4.2.5 Blowing in pellets for a store with pellet screw
r
Switch off the boiler by tapping “Boiler off” at the mode icon and allow to cool for at
least two hours
r
Close all openings to the store to seal out dust
r
Blow the fuel into the store