Frigiking FD350 Owner'S Manual Download Page 1

1-999-1539 REV  A

09/11/17

Owner’s Guide

 

Use and Care Manual

Customer Service 
1-800-325-6952

• 

Safety 

• Installation 
• Start-up

• Operation 
• Maintenance 
• Troubleshooting

Ducted  Cooler  Models:        
FD350, FD450, FD650  
FS350, FS450, FS650

Congratulations:

 You have purchased a product of superior performance and design, which will give the best service when 

properly installed, operated and maintained.

• Read all instructions carefully before installation.
• Cooler motor, pump, cabinet and junction box must be 

grounded in accordance with all local and national codes. 
A ground wire must be used between the cooler and the 
power source.

• Always disconnect electrical power to the cooler before 

working on cooler.

• 

WARNING

 To reduce the risk of fire or electrical shock 

do 

NOT

 use this fan with any solid state speed control 

device.

• Do 

NOT

 remove side panels while cooler is running.

• Do 

NOT

 operate with evaporative pad removed.

• Do 

NOT

 locate cooler near exhaust or vent pipes as 

odors or fumes may be drawn into the unit.

• Be sure cooler is connected to proper line voltage 

stamped on blower motor and pump motor specification 
plate. 

NOTE: IMPROPER VOLTAGE WILL VOID MOTOR 
WARRANTY.

READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS

    WARNING

 - 

TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO 

PERSONS, OBSERVE THE FOLLOWING:

This guide will provide you with information needed to assemble the unit. It also contains information on how to safely operate, 
inspect, maintain and troubleshoot your Frigiking evaporative air cooler.

THE USE OF ANODE DEVICES, CHEMICAL ADDITIVES, OR 
COOLER CLEANER TREATMENTS IN THIS COOLER WILL 
VOID THE WARRANTY.

Model #                        Serial # 
Date of Purchase: 
Place of Purchase:

Serial # can be found outside the cabinet.

• Your warranty does 

NOT

 cover shipping damage. Report 

all shipping damage at once to store making the delivery.

• For future reference, record the model and serial number, 

date and place of purchase of your evaporative cooler 
here:

Summary of Contents for FD350

Page 1: ...operate with evaporative pad removed Do NOT locate cooler near exhaust or vent pipes as odors or fumes may be drawn into the unit Be sure cooler is connected to proper line voltage stamped on blower motor and pump motor specification plate NOTE IMPROPER VOLTAGE WILL VOID MOTOR WARRANTY READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK OR INJURY T...

Page 2: ...ative coolers should not be connected to a soft water system DRAIN BUSHING Insert drain bushing through the hole in the cooler bottom pan Attach nut securely and hand tighten Do NOT use a wrench WALL SWITCH For one or two speed 120 ro 240 volt use switch kit available from your dealer ADJUSTABLE MOTOR PULLEY SHEAVE This part is set at the factory for proper motor load and maximum air delivery of a...

Page 3: ...creases power consumption and shortens belt and motor life Install belt over motor and blower pulleys A check belt tension by squeezing deflecting belt Proper tension will allow deflection of 1 2 to 3 4 inch B To increase or decrease belt tension loosen bolt in slot of motor support brcket Adjust belt to desired tension and re tighten bolt OPERATION PRE WET PADS For maximum cooling efficiency prio...

Page 4: ...placement if required and pad replacement WARNING ALWAYS DISCONNECT ELECTRICAL POWER TO THE COOLER BEFORE WORKING ON COOLER TROUBLESHOOTING The following guide is intended to help you diagnose and fix some of the most commonly encountered problems by no means does this guide cover all of the possible problems you may encounter If you cannot diagnose and correct the problem or if it persists contac...

Page 5: ... reparacion ADVERTENCIA Para reducir el riesgo de incendio o toque electrico no use este enfriador con ningün dispositivo para controlar la velocidad NO remueva los filtros cuando la unidad esta fundonando No opere con almohadilla de evaporación extraído NO instale el enfriador cerca de extractores a lubos de vneteo y que alares a vapores pueden entrar a la unidad Asegurese que el enfriador sea co...

Page 6: ...uerca Tubo 0 635 cm de pulgada plastico o cobre BUJE DE DRENAJE Inserte el buje de drenaje atraves de el agujero en el fondo de el enfriador Atormille la tuerca con la presion de la mano no use herramienta INTERRUPTOR DE PARED Para una o dos velocidades 120 o 230 use el juego de interruptor disponible con su distribuidor POLEA MORTIZ AJUSTABLE Esta parte es ajustada en la fabrica para la propia ca...

Page 7: ...nguera de jardin Ponga los filtros remojados en el enfriador y ponga a funcionar el motor y la bomba COMPUERTA DE INVIERNO EMPOTRADA Unidades de descarga inferior solamente Una caracteristica exclusiva de su enfriador modelos en el rango de 4800 a 6800 PCM que es proveido por la compuerta de que cierra completamente Su enfriador es enviado de la fabrica con la compuerta temporalmente sujetada a el...

Page 8: ...uera de jardín antes de reinstalarlos Solución de problemas La siguiente guía está pensada para ayudarle a diagnosticar y solucionar algunos de los problemas más comúnmente encontrados de niguna manera esta guía cubre todos los posibles problemas que pueden surgir Si no puede diagnosticar y corregir el problema o si persiste póngase en contacte con un personal de servicio cualificado Todo el traba...

Reviews: