Summary of Contents for SGER341AS0

Page 1: ...ual must be followed to minimize the risk of fire or explosion or to prevent property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquid in the vicinity of this or any other appliance WHATTO DO IFYOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Clear the room building or ar...

Page 2: ...hich has a swing out damper s that open when the dryer is in operation When the dryer stops the dampers automatically close to prevent drafts and the entrance of insectsand rodents Toavoid restricting the outlet maintain a minimum of 12 inches 30 5 cm clearance between the vent hood and the ground or any other obstruction The following are specific requirements for proper and safe operation of you...

Page 3: ...increase in vent restriction The exhaust system should be inspected and cleaned a minimum of every 18 months with normal usage The more the dryer is used the more often you should check the exhaust system and vent hood for proper operation EXHAUST DIRECTION All dryersshipped from the factory are set up for rear exhausting However on electric dryers exhausting can be to the right or leR side of the...

Page 4: ...ed A Iouvered door with equivalent air openings for the full length of the door is acceptable MINIMUM INSTALLATION CLEARANCES Inches FRONT SIDES REAR TOP Alcove or Under counter 0 0 cm 0 0 cm 0 0 cm 15 38 1 cm Closet 1 2 54 cm 0 0 cm 0 0 cm 15 38 1 cm Closet door ventilation required 2 Iouvered openings each 60 square inches 387 square centimeters 3 inches 7 6 cm from bottom and top of door THIS D...

Page 5: ...ed to the floor Mobile Home Installation Kit No 169840 is available from your dealer 5 Refer to pages 2 and 3 for other important venting requirements 6 Installation MUST conform to current Manufactured Home Construction Safety Standard which is a Federal Regulation Title 24 CFR Part32 80 or when such standard is not applicable with American National Standard for Mobile Homes In Canada the CSA Z24...

Page 6: ...R SWING Your dryer is designed so the door swing may be reversed at any time without additional parts Conversion is accomplished by transferring hinges to the opposite side of the cabinet To change the direction of the door opening 1 Open the dryer door Removethe four hinge hole plugs from the left side of the door opening Place nearby for future installation NOTE You may need a plastic knife to h...

Page 7: ...nected to the equipment grounding terminal or lead on the appliance Canadian ELECTRIC Dryer J _ Improper connection of the equipment grounding conductor can result in a risk of electrical shock Check with a licensedelectrician if you arein doubt asto whether the appliance is properly grounded For agrounded cord connected dryer 1 The dryer must be grounded In the event of a malfunction or breakdown...

Page 8: ...the terminal block cover GREEN GROUND WIRE RED BLACK TIGHTEN NUT _ HITE TO THESE THREADS NUT 1 STRAIN _ RELIEF MOUNTING BRACKET POWER CORD ELECTRICAL CONNECTIONS FOR 4 WIRE SYSTEM I Non Canadian ELECTRIC Dryer I 1 Remove the screws securing the terminal block accesscover and the strain relief mounting bracket located on the back of the dryer upper corner 2 Install a U L approved strain relief in t...

Page 9: ...ture included with this dryer are not meant to cover every possible condition and situation that may occur Good safe practice and caution MUST be applied when installing operating and maintaining any appliance 3 With the dryer in its final position adjust one or more of the legs until the dryer is resting solid on all four legs Place a level on top of the dryer THE DRYER MUST BE LEVEL AND RESTINGS...