SERVICE DATA SHEET
241582301
ICE & WATER - AUTOMATIC DEFROST
COUNTER DEPTH SIDE BY SIDE - R134a
IMPORTANT SAFETY NOTE
The information provided herein is designed to assist
qualified repair personnel only. Untrained persons should
not attempt to make repairs due to the possibility of
electrical shock. Disconnect power cord before servicing
this appliance.
IMPORTANT
If any green grounding wires are removed during servicing,
they must be returned to their original position and properly
secured.
CAUTION
All electrical parts and wiring must be shielded from torch
flame. DO NOT allow torch to touch insulation; it will char
at 200°F and flash ignite (burn) at 500°F. Excessive heat
NOTE
This product comes equipped with an Adaptive Defrost
Control (ADC). To activate manual defrost, press and hold
the Freezer temperature UP (WARMER) key while pressing
the Fresh Food temperature DOWN (COLDER) key 5 times
within 6 seconds. A “d” in the freezer temperature window
and “F” in the refrigerator temperature window will display
when the heater is activated. To deactivate manual defrost,
press and hold Freezer temperature UP (WARMER) key
while pressing the Fresh Food temperature DOWN
(COLDER) key 5 times within 6 seconds. “d” and “F” will
be displayed until the defrost cycle is complete. (approx. 8
minutes)
IMPORTANT
Please return this sheet to its original location.
ICE MAKER INFORMATION
Test Cycling
Press the momemtary contact on the ON/OFF switch for
approximately 15 seconds. Ice maker will continue to
complete the cycle.
Water Fill Volume
Remove cover by
inserting screwdriver
in notch at bottom
and prying cover from
housing. The water fill
adjustment screw will
change the fill time.
One turn is equal to
20cc (.68 oz.). The
correct fill is 102 to
110cc (3.25 to 3.5 oz.). When a water valve is replaced,
the fill volume must be checked
TUR
N
Mounting
Plate
Screws
Mounting
Plate
Screw
Motor
Gear
Timing
Gear
Water Fill
Adjustment
Ice Maker
ON/OFF
Switch
PERFORMANCE DATA
NO LOAD AND NO DOOR OPENINGS AT 37°F & 0°F CONTROL SETTING
Type A with Run/Start Capacitor
65°F (18°C) Ambient
90°F (32°C) Ambient
Operating Time
32 TO 40%
55 TO 65%
Freezer Temperature
0° TO 4°F
-18° to -16°C
-1° TO 3°F
-18° to -16°C
Refrigerator Temperature
34° TO 39°F
1° to 4°C
34° TO 39°F
1° to 4°C
Low Side Pressure (cut-in)
5 to 12 psig
34 to 83 kPa
5 to 12 psig
34 to 83 kPa
Low Side Pressure (cut-out)
-2 to 2 psig
-14 to 14 kPa
-2 to 2 psig
-14 to 14 kPa
High Side Pressure (last 1/3 of cycle)
90 to 115 psig
621 to 793 kPa
130 to 155 psig
896 to 1069 kPa
Wattage (last 1/3 of cycle)
120 to 150
130 to 160
Amps (running)
1.0 to 1.4
1.1 to 1.5
Base Voltage
115 vac (127 vac max)
115 vac (127 vac max)
DEFROST SPECIFICATIONS
Thermostat Heater
Cabinet Size
Cut-In Cut-Out
Watts Ohms
23’
25°F
-4°C
47°F
8°C
450 30
Electronic Timer–(ADC) Defrost 24 minutes every 6 to 96 hours of compressor run time.
CONDENSER FAN MOTOR
Watts RPM
Amps
2.8
950 CW Opposite Shaft
.1 Running
ICE MAKER SPECIFICATIONS
Electrical
115 vac (127 vac max)
Thermostat
Opens at 48°F (9°C)
Closes at 15°F (-9°C)
Heater Wattage
85
ICE MAKER CONNECTOR PLUG CONNECTIONS
Wire Number
Wire Color
Connects to:
1
Green/Yellow Ground
2
Yellow Water
Valve
3
Black Line
4
Light Blue
Neutral
®
Summary of Contents for GLRT188WDZ0