background image

SERVICE DATA SHEET

241582301

ICE & WATER - AUTOMATIC DEFROST

COUNTER DEPTH SIDE BY SIDE - R134a

IMPORTANT SAFETY NOTE

The information provided herein is designed to assist
qualified repair personnel only. Untrained persons should
not attempt to make repairs due to the possibility of
electrical shock. Disconnect power cord before servicing
this appliance.
IMPORTANT
If any green grounding wires are removed during servicing,
they must be returned to their original position and properly
secured.

     

CAUTION

All electrical parts and wiring must be shielded from torch
flame. DO NOT allow torch to touch insulation; it will char
at 200°F and flash ignite (burn) at 500°F. Excessive heat

NOTE

This product comes equipped with an Adaptive Defrost
Control (ADC). To activate manual defrost, press and hold
the Freezer temperature UP (WARMER) key while pressing
the Fresh Food temperature DOWN (COLDER) key 5 times
within 6 seconds. A “d” in the freezer temperature window
and “F” in the refrigerator temperature window will display
when the heater is activated. To deactivate manual defrost,
press and hold Freezer temperature UP (WARMER) key
while pressing the Fresh Food temperature DOWN
(COLDER) key 5 times within 6 seconds. “d” and “F” will
be displayed until the defrost cycle is complete. (approx. 8
minutes)

IMPORTANT

Please return this sheet to its original location.

ICE MAKER INFORMATION

Test Cycling

Press the momemtary contact on the ON/OFF switch for
approximately 15 seconds. Ice maker will continue to
complete the cycle.

Water Fill Volume

Remove cover by
inserting screwdriver
in notch at bottom
and prying cover from
housing. The water fill
adjustment screw will
change the fill time.
One turn is equal to
20cc (.68 oz.). The
correct fill is 102 to
110cc (3.25 to 3.5 oz.). When a water valve is replaced,
the fill volume must be checked

TUR

N

Mounting
Plate
Screws

Mounting

Plate

Screw

Motor
Gear

Timing

Gear

Water Fill
Adjustment

Ice Maker
ON/OFF
Switch

PERFORMANCE DATA 

NO LOAD AND NO DOOR OPENINGS AT 37°F & 0°F CONTROL SETTING 

Type A with Run/Start Capacitor 

65°F (18°C) Ambient 

90°F (32°C) Ambient 

Operating Time 

32 TO 40% 

55 TO 65% 

Freezer Temperature 

0° TO 4°F 

-18° to -16°C 

-1° TO 3°F 

-18° to -16°C 

Refrigerator Temperature 

34° TO 39°F 

1° to 4°C 

34° TO 39°F 

1° to 4°C 

Low Side Pressure (cut-in) 

5 to 12 psig 

34 to 83 kPa 

5 to 12 psig 

34 to 83 kPa 

Low Side Pressure (cut-out) 

-2 to 2 psig 

-14 to 14 kPa 

-2 to 2 psig 

-14 to 14 kPa 

High Side Pressure (last 1/3 of cycle) 

90 to 115 psig 

621 to 793 kPa 

130 to 155 psig 

896 to 1069 kPa 

Wattage (last 1/3 of cycle) 

120 to 150 

130 to 160 

Amps (running) 

1.0 to 1.4 

1.1 to 1.5 

Base Voltage 

115 vac (127 vac max) 

115 vac (127 vac max) 

DEFROST SPECIFICATIONS 

Thermostat Heater 

Cabinet Size 

Cut-In Cut-Out 

Watts Ohms 

23’ 

25°F 
-4°C 

47°F 

8°C 

450 30 

Electronic Timer–(ADC) Defrost 24 minutes every 6 to 96 hours of compressor run time. 

CONDENSER FAN MOTOR 

Watts RPM 

Amps 

2.8 

950 CW Opposite Shaft 

.1 Running 

ICE MAKER SPECIFICATIONS 

Electrical 

115 vac (127 vac max) 

 

Thermostat 

Opens at 48°F (9°C) 

Closes at 15°F (-9°C) 

Heater Wattage 

85 

 

ICE MAKER CONNECTOR PLUG CONNECTIONS 

Wire Number 

Wire Color 

Connects to: 

Green/Yellow Ground 

Yellow Water 

Valve 

Black Line 

Light Blue 

Neutral 

 

®

Reviews: