Page 1: ...al applications such as restaurants or beauty salons etc Antes de comenzar la instalacion lea cuidadosamente estas instrucciones Esto simplificar4 la instalad6n y asegurar4 que a secadora se instale correctamente y de manera segura Despu_s de completar la instaladon coloque estas instrucciones cerca de la secadora para referencia futura NOTA La alimentaci6n electrica para la secadora debera cumpli...

Page 2: ... volt single phase 60 Hz Alternating Current POWER SUPPLY CORD KIT The dryer MUST employ a 3 conductor power supply cord NEMA 10 30 type SRDT rated at 240 volt AC minimum 30 amp with 3 open end spade lug connectors with upturned ends or closed loop connectors OR a 4 conductor power supply cord NEMA 14 30 type SRDT or ST as required rated at 240 volt AC minimum 30 amp with 4 open end spade lug conn...

Page 3: ...ard as well as increase drying times Do not screen the exhaust ends of the vent system nor use any screws or rivets to assemble the exhaust system Lint can become caught in the screen on the screws or rivets clogging the duct work and creating a fire hazard as well as increasing drying times Use an approved vent hood to terminate the duct outdoors and seal all joints with duct tape All male duct p...

Page 4: ... The gas supply line should be of I 2 inch 1 27 cm pipe 3 If codes allow flexible metal tubing may be used to connect your dryer to the gas supply line The tubing MUST be constructed of stainless steel or plastic coated brass 4 The gas supply line MUST have an individual shutoff valve 5 A I 8 inch 0 32 cm N RT plugged tapping accessible for test gauge connection MUST be installed immediately upstr...

Page 5: ...ers 3 inches 7 6 cm from bottom and top of door NOTE Under counter and stack models O inches O cm for sides rear and top This dryer MUST be exhausted outdoors 5 The following illustrations show minimum clearance dimensions for proper operation in a recess or closet installation II e _ll _ 0 cm II ol II 1 _11_ 2 54 cm ii n _ _ 0 0 cm 60 sq inches 387 1 sq cm 60 sq inches 387 1 sq cm CLOSET DOOR Ii ...

Page 6: ...nobs 70 49cm 28 5 to clear door handle 72 39cm l Electrical supply on rear of unit o o _ _ _ i J I T __ __ 34 29cm To rear base exhaus 27 0 36 91 44cm 68 58cm Stacked Dryer insta ation Dimensions T 72 00 11 12cm 182 88cm 4 375 Side exhausts i 28 25 to front of cabinet 71 76cm 28 75 to clear knobs 73 03cm 29 5 to clear door handle 49 to clear open door 124 46cm 41 00 104 14cm Center line height for...

Page 7: ... or ANSI UL2158 CAN CSA C22 2 latest editions for HOME USE only O Correct UNPACKING 1 Using the four shipping carton corner posts two on each side carefully lay the dryer on its left side and remove the foam shipping base To prevent damage do not use the control panel as a means to pick up or move the dryer 2 Return the dryer to an upright position FOAM SHIPPING _P_C KING REVERSING DOOR SWING Your...

Page 8: ...remove the plugs Be careful to avoid scratching the paint 5 Remove the two handle screws and remove the handle by pulling straight out from door 6 Install the plugs from Step 3 into the holes left by removing the handle screws in Step 4 7 Lay the door on a flat surface and support the edges of the door to keep it from turning Apply moderate downward pressure on the lens with both hands and rotate ...

Page 9: ...e is a copper wired power cord with a copper wired receptacle NOTE Dryers operating on 208 volt power supply will have longer drying times than operating on 240 volt power supply 2 If your dryer is equipped with a power supply cord having an equipment grounding conductor and a grounding plug the plug MUST be plugged into an appropriate copper wired receptacle that is properly installed and grounde...

Page 10: ...es not turn g Reinstall tile terminal block cover GROUND WIRE i I RE _VHITE STRAIN RELIEF _ MOUNTING_ BRAC KET_ POWER CORD TIGHTEN NUT TO THESE THREADS N UT II ELECTRICAL CONNECTIONS FOR 4 WiRE SYSTEM ELECTR C Dryer Remove the screws securing the terminal block access cover and the strain relief mounting bracket located on the back of the dryer upper cornen Install a U L approved strain relief in ...

Page 11: ...es clothing etc obstructs the flow of combustion and ventilation air 5 Run the dryer through a cycle check for proper operation NOTE On gas dryers before the burner will light it is necessary for the gas line to be bled of air If the burner does not light within 45 seconds the first time the dryer is turned on the safety switch will shut the burner off If this happens turn the timer to OFF and wai...