2

PRE-INSTALLATION REQUIREMENTS

Tools Required for Installation:

1. 3/8 in. socket with ratchet.
2. Channel-lock adjustable pliers.
3. Carpenter’s level.

ELECTRICAL REQUIREMENTS

CIRCUIT

 - Individual, properly polarized and grounded

15 amp. branch circuit fused with 15 amp. time delay
fuse or circuit breaker.

POWER SUPPLY

 - 2 wire, with ground, 120 volt, single

phase, 60 Hz, Alternating Current.

OUTLET RECEPTACLE

 - Properly grounded 3-prong

receptacle to be located so the power supply cord is
accessible when the washer is in an installed position.

GROUNDING REQUIREMENTS

4.

Grounded cold water pipe 

MUST

 have metal

continuity to electrical ground and 

MUST

 register no

more than 25 ohms resistance. It 

MUST

 not be

interrupted by plastic, rubber, or other electrical
insulating connectors such as hoses, fittings,
washers, gaskets (including water meter or pump).
Any electrically insulated connector should be
jumped with a length of No. 4 copper wire securely
clamped to bare metal at both ends with a UL
approved ground clamp.

5.

If a grounded water pipe is not available, a ground
rod

 MUST

 be used and register no more than 25

ohms resistance when in the ground. Drive the rod
into the ground outside the dwelling and connect a
grounding wire (12 AWG or heavier) between the
grounding screw and the grounding rod. It may take
more than one ground rod to not exceed 25 ohms
resistance to ground.

WATER SUPPLY REQUIREMENTS

Hot and cold water faucets 

MUST

 be installed within 42

inches (107 cm) of your washer’s water inlet. The faucets

MUST

 be 3/4 inch (1.9 cm) garden hose type so inlet

hoses can be connected. Water pressure 

MUST

 be

between 10 and 120 pounds per square inch (maximum
unbalance pressure, hot vs. cold, 10 psi.) Your water
department can advise you of your water pressure. The
hot water temperature should be about 140 degrees F
(60 degrees C).

DRAIN REQUIREMENTS

1.

Drain capable of eliminating 17 gallons (64.3 L) per
minute.

2.

A standpipe diameter of 1-1/4 in. (3.18 cm) minimum.

3.

The standpipe height above the floor should be:

Minimum height:

33 in. (83.82 cm)

Maximum height:

96 in. (244 cm)

  Improper connection of the equipment

grounding conductor can result in a risk of electrical
shock. Check with a licensed electrician if you are in
doubt as to whether the appliance is properly grounded.

1.

The washer 

MUST

 be grounded. In the event of a

malfunction or breakdown, grounding will reduce the
risk of electrical shock by a path of least resistance
for electrical current.

2.

Since your washer is equipped with a power supply
cord having an equipment-grounding conductor and
a grounding plug, the plug 

MUST

 be plugged into

an appropriate, copper wired receptacle that is
properly installed and grounded in accordance with
all local codes and ordinances or in the absence of
local codes, with the National Electrical Codes,
ANSI/NFPA 70 (latest
edition). If in doubt, call a
licensed electrician. 

DO

NOT

 cut off or alter the

grounding prong on the
power supply cord. In
situations where a two-
slot receptacle is present,
it is the owner’s responsi-
bility to have a licensed electrician replace it with a

properly grounded

 three prong grounding type

receptacle.

3.

For added personal safety, connect a separate
ground wire (No. 18 minimum) from a top panel hinge
screw on the rear of the washer to a grounded cold
water pipe. 

DO NOT

 ground to a gas supply pipe or

hot water pipe.

96" Max.
(244 cm)

33" Min.
(83.82 cm)

NOTE:

For installations requiring a longer drain hose, have
a qualified technician install a longer drain hose, P/
N 134049201. For drain systems in the floor, install
a syphon break kit,available from your local
hardware store.

Summary of Contents for Gallery GLWS1649AS2

Page 1: ...n for future reference NOTE The electrical service to the washer must conform with local codes and ordinances and the latest edition of the National Electrical Code ANSI NFPA 70 or in Canada CSA 22 1 Canadian Electrical Code Part 1 Contents SUBJECT PAGE Pre Installation Requirements 2 Electrical Requirements 2 Grounding Requirements 2 Water Supply Requirements 2 Drain Requirements 2 Rough In Dimen...

Page 2: ...ld 10 psi Your water department can advise you of your water pressure The hot water temperature should be about 140 degrees F 60 degrees C DRAIN REQUIREMENTS 1 Drain capable of eliminating 17 gallons 64 3 L per minute 2 Astandpipe diameter of 1 1 4 in 3 18 cm minimum 3 The standpipe height above the floor should be Minimum height 33 in 83 82 cm Maximum height 96 in 244 cm Improper connection of th...

Page 3: ...ate the tub blocking pad shipping bolt and plastic spacer block should be retained MECHANISM SHIPPING BOLT PLASTIC SPACER BLOCK SHIPPING BLOCKS DRAIN HOSE POWER CORD FOAM SHIPPING PAD SHIPPING CARTON CORNER POSTS 3 Return the washer to an upright position 4 Remove the tape holding the lid shut and open the lid 5 Remove the foam tub blocking pad 6 Remove the inlet hoses and enclosure package from t...

Page 4: ... the power cord into an outlet 9 Turn on the power at a circuit breaker fuse box 10 Read the Operating Instructions and Owner s Guide provided with the washer They contain valuable and helpful information that will save you time and money 11 Run the washer through a complete cycle Check for water leaks and proper operation 12 If your washer does not operate please review the Avoid Service Checklis...

Reviews: