Electrical Shock and Personal Injury Hazard
Electrical ground is required on this appliance.
DO NOT ground to a gas line.
If cold water pipe is interrupted by plastic,
non-metallic gaskets, or other insulating
materials, DO NOT use for grounding.
Check with a qualified electrician if you are in
doubt as to whether the appliance is properly
grounded.
DO NOT modify power supply cord plug. If it
does not fit outlet, have a proper outlet
installed by a qualified electrician.
DO NOT have a fuse in the neutral or
grounding circuit. A fuse in the neutral, or
grounding circuit could result in an elecrtrical
shock.
DO NOT use an extension cord with this
appliance.
Failure to follow these instructions could result in
electrical shock, serious injury, or death.
WARNING
Installation Instructions
For Slider Casement Air Conditioners
NOTE:
These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash,
or installation in a metal CASEMENT window. Modification may be necessary when installing in windows made
differently than those shown in these instructions.
A high window accessory kit is available for window heights up to 62" (1575mm). Part # EA103W.
Meeting Electrical Requirements
OBSERVE ALL LOCAL GOVERNING CODES
AND ORDINANCES.
DO NOT, UNDER ANY CIRCUMSTANCES,
REMOVE THE POWER SUPPLY CORD
GROUNDING PRONG.
ELECTRICAL REQUIREMENTS
A 115 volt (103.5 minimum, 126.5 maximum), 60
Hertz, AC only, 15 ampere fused electrical supply
is required. A time delay fuse or time delay circuit
breaker is also required. A separate circuit, serving
only this appliance, MUST be provided.
NOTE:
If codes permit, and a separate
grounding wire is used; it is recommended that a
qualified electrician determine that the grounding
path is adequate and not interrupted by plastic,
non-metallic gaskets, or other insulating materials.
RECEPTACLE WIRING
Receptacle wiring should be a minimum of 14
gauge. Use copper wire only. It is your responsibility
to provide proper and adequate receptacle wiring,
installed by a qualified electrician.
P/N
220215A055
SUBJECT PAGE
Meeting Electrical Requirements 1
Electrical Connection 2
Preparing For Installation 2
Installing Unit in a Sliding Window 4
Alternate Window Jamb Applications 7
Installing Unit in a Casement Window 8
TABLE OF CONTENTS