Page 1: ...ervice must be performed by a qualified installer service agency or the gas supplier Additional Safeguards Do not install wall oven beneath the work counter The flue charge shall not be located below the 36 level 5 16 42 41 uh6 37 s s I 23 Ws2 _l_21 Model with 2 oven cavities Model with lYz oven cavity Clearance for complete door opening For model with 2 cavities allow at least 1 7 5 8 For model w...

Page 2: ... NFPA 501 A latest edition or with local codes Do not store items or food of interest to children in the cabinets above the appliance Children could be seriously burned or injured if they climb on the appliance to reach these items Do not store or use gasoline or other flammable vapors and liquids near this or any other appliance Explosions or fires could result Be certain all packing materials ar...

Page 3: ... the appliance when installed must be electrically grounded in accordance with local codes or in their absence of local codes with the National Electric Code ANSI NFPA No 70 1987 or latest edition Check all code rules and regulations for connecting the wall oven to be certain the installation conforms with all local municipal and state codes as well as local utility regulations Failure to comply w...

Page 4: ...ate holes in the side extension panels and sides of the oven Put the 6 screws back 5 Proceed with oven installation Return to upright position Oven Bottom Panel Figure 5 5 Cabinet Installation A Model With lYz Oven Cavity Insert appliance into cutout Use the 4 mounting screws provided to fasten the front frame of the appliance to the cabinet steps 1 below Keep the 2 decorative screws to fix the de...

Page 5: ...ollar it will be neces sary to move control panel out of the way and reach in to drive screw Maintain minimum 1 clearance between the vent pipe and surrounding combustible surfaces as stated on serial plate Figure 8 7 Provide an Adequate Gas Supply Important Read these instructions carefully before connecting this unit to a gas supply The units covered in these instructions are designed to operate...

Page 6: ...leak detector at alljoints and connections Tighten all connections if necessary to prevent gas leakage in the wall oven or supply line IMPORTANT A pipe joint sealant resistant to the action of LP Gas must be used on all pipe connections Do not use a flame to check for leaks from gas connections Checking for leaks withaflame may result in a fire or explosion Disconnect the oven and its individual s...

Page 7: ...exposed end of the plunger E Replace the cap on the pressure regulator F Turn the valve hoods approximately 2 1 2 turns counterclockwise This will move the hood away from the mixer pin G Apply gas adjust pilots and burner air shutter for proper flame H There should be 4 WC pressure in the manifold after conversion for proper operation on Natural Gas 11 Adjustments Oven Broiler Flame Adjustment The...

Page 8: ... Model and Serial Number Location The serial plate is located on the left side inner trim of the oven for the model with 1 Y_oven cavity and on the lower oven frame for the model with 2 oven cavities When ordering parts for or making inquires about your wall oven always be sure to include the model and serial numbers and a lot number or letter from the serial plate of your appliance Your serial pl...

Page 9: ...alizados por un instalador calificado por un servicio tecnico certificado o por el abastecedor de gas Medidas de seguridad adicionales No instale horno de pared debajo de la mesa de trabajo La salida de descarga no debe estar por debajo de 36 de altura I_F 22s 16 _ _ _ I_ 42 Modelos con 2 cavidades de horno 23 7Is Modelos con f23 s d 3 s s _25 s s Y_ cavidad de horno Espacio libre para abrir compl...

Page 10: ...jetos de interes para los ninos en alacenas ubicadas 10 encima de la estufa o en la guarda posterior de esta Los ninos pueden quemarse o lastimarse seriamente si se suben en la estufa para alcanzar estos objetos No guarde o haga uso de gasolina o otros vapores 3 liquidos inflamables acerca de este o cualquier aparato Se puede resultar en incendios o explosiones Asegurese de remover todo el materia...

Page 11: ...rdo las National Electrical Code ANSI NFPA No 70 1987 o ultima edicion Verifique todos los codigos normas o regulaciones para cerciorarse que la instalacion esta de acuerdo a los codigos locales estatales y de las empresas de servicio de energia locales El incumplimiento las anteriores recomendaciones puede resultar en un peligroso coque electrico Nota Todas las conexiones y ajustes deben de ser r...

Page 12: ...sion con los delasparedeslateralesdelhomo Vuelva a colocar los 6 tornillos 5 Procedaconlainstalaciondelhomo Vuelvaa colocar el horno sobre su base Puerta del horno Fondo del Panel de extension homo Figura 5 5 Instalacion del gabinete A Modelo con una cavidad de 1 1 zpara el homo Introduzca el artefacto en el espacio designado Use los 4 tornillos para fijar la parte delantera del artefacto al gabin...

Page 13: ...a 8 Para ajustar el tubo a la salida es necesario remover el panel de controles para poder alcanzar el tornillo Guarde al menos 1 de margen libre entre la tuberia de ventilacion y los elementos combustibles vecinos como Io establece la placa de serie Remue B1 tubo de ventilacion IA_ 4 I D Tubo para A II II fijar a salida __ _ rlde ventilacion Figura 8 7 Provea un adecuado suministro de gas Importa...

Page 14: ...nto de la vuelta al suministro de gas de la cocina y utilice un detector de fugas Iiquidas o agua y jabOn en todas las articulaciones y conexiones para verificar si existen fugas Valvula exterior de cierre _ Figura 9 Si se utiliza conectador de gas flexible la linea de gas deberzi ser de diseno A G A certificado Valvula de seguridad Platina de soporte de la i valvula de cierre B Modelo con 2 cavid...

Page 15: ...sido calibrado el regulador esta indicado en la parte superior del piston GRANDE extremidad hacia el regulador para Gas L P Figura 11 PEQUEI_IA extremidad hacia el regulador para gas unta natural B Ajuste del orificio del quemador del horno vea figura 12 Pasador _Nat _JJ unt de 11 bellota del quemador Figura 12 Usando una Ilave de Y_ giro hacia abajo lajunta en forma de bellota ajustable que inyec...

Page 16: ...entradainsuficientedeairecausariala coloraciOn amarilla del borde externo de la llama yla formaciOn de hollin Recuerde el homo sera despacho de la fabrica preparado para trabajar con gas natural a menos que se especifiquealgodiferente isevaaconectara LPG35 asegurese de seguir el procedimiento indicado en ConversiOn para cambiar el regulador y el orificio del quemador a la ubicacion LP Para determi...

Page 17: ... bajo del homo para modelos con 2 cavidades de homo Asegurese de incluir el modelo numero de serie y el numero o letra de Iote que se encuentran en la placa en todo pedido de partes o solicitud de informacion acerca de su homo empotrado La placa de numero de serie tambien indica las especificaciones de los quemadores el tipo de combustible y la presion para la cual fue ajustada el homo empotrado e...

Page 18: ...UPTDR DE LUZ DE HORNB OVEN LAMP LUZ DE HQRNO CONNECTOR CBNECTDR CLOCK RELQJ 0 OVEN THERMOSTAT TERMOBTATO DE HORNB o CONNECTOR CONECTOR CONNECTOR CONECTOR OVEN IGNITER ENCENDIDB DE HORNO OVEN VALVE VALVULA DE HORNB CAUTION LABEL ALL WIRES PRIOR T_ DISCONNECTION WHEN SERVICING CBN1ROLS WIRING ERROR CAN CAUBB IMPROPER AND DANGEROUS OPERATION VERIFY PROPER OPERATION AFTER SBRVIC NG AV BO ETIQUETE TOBO...

Page 19: ...N CONNECTOR OVEN LAMP SWITCH CONNECTOR OVEN LAMP W I RI W i B IGNITER CONNECTOR BR I ON TER CONNECTOR W 1 BAKE IGNITER ELECTRONIC OVEN CONTROL BAKE VALVE V I V 1 TEMPERATURE PROBE H3173 CAUTION LABEL ALL W RES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS WIRINGS ERROR CAN CAUSE IMPROPER AND DANGEROUS OPEBATEON VERIFY PROPER OPERATION AFTER SERVICING 318046309 REV A ...

Page 20: ... I NC _s SL A lATCH MOTOR BR 1 0 NC BAKE VALVE BRO I L I GN TER BL 1 W I BROIL VALVE rAN MOTOR I NC J _ SW B FAN W 1 4 I W 1 W I WARN I NG D ISCONNE I POWER BEFORE SERV C NG UN I BL L I I COLOR WIRE NO COLOR CODE NOTE CIRCUIT SHOWN WITH CONTROLS SET TO OFF OVEN DOOR CLOSED AND UNLOCKED SW SW A LATCH SWITCH SW B FAN SWIICII 31804631 I REV A 2O ...