background image

1

 

 

 

P/N  134528200A (0501)

Before beginning installation, carefully read these instructions. This will simplify the installation and ensure the dryer is installed
correctly and safely. Leave these instructions near the Dryer after installation for future reference.

NOTE: 

The electrical service to the Dryer must conform with local codes and ordinances and the latest edition of the National Electrical Code, ANSI/

NFPA 70.

NOTE: 

The gas service to the Dryer must conform with local codes and ordinances and the latest edition of the National Fuel Gas Code ANSI

Z223.1.

NOTE: 

The Dryer is designed under ANSI Z 21.5.1  or ANSI/UL 2158 - CAN/CSA C22.2 (latest editions) for 

HOME USE only

. This Dryer is not

recommended for commercial applications such as restaurants or beauty salons, etc.

Antes de comenzar la instalación, lea cuidadosamente estas instrucciones. Esto simplificará la instalación y asegurará que la secadora
se instale correctamente y de manera segura. Después de completar la instalación, coloque estas instrucciones cerca de la secadora
para referencia futura.

NOTA: 

La alimentación eléctrica para la secadora deberá cumplir con los códigos y reglamentos locales y con la última edición del Código Eléctrico

Nacional, ANSI/NFPA 70.

NOTA:

 La alimentación de gas para la secadora deberá cumplir con los códigos y reglamentos locales y con la última edición del Código Nacional para

Gases Combustibles, ANSI Z223.1.

NOTA: 

La secadora está clasificada para 

USO DOMESTICO solamente

, de acuerdo con la norma ANSI Z 21.5.1 o ANSI/UL 2158 - CAN/CSA C22.2 (las

últimas ediciónes). Esta secadora no se recomienda para uso commercial tal como en restaurantes, salones de belleza, etc.

Pre-Installation Requirements....................................2
Electrical Requirements............................................2
Exhaust System Requirements............................... 3-4
Gas Supply Requirements........................................ 4
Location of Your Dryer...........................................4-5
Rough-In Dimensions...............................................6
Mobile Home Installation.........................................7
Unpacking ............................................................7
Reversing Door Swing...........................................7-8
Electrical Installation............................................... 9
Grounding Requirements......................................... 9
Electrical Connections—3-wire............................... 10
Electrical Connections—4-wire............................... 10
Gas Connection.....................................................11
General Installation................................................11
Replacement Parts.................................................11
Requerimientos de instalación preliminares...............12
Requerimientos eléctricos.......................................12
Requerimientos del sistema de escape..................12-13
Requerimientos del suministro de gas........................13
Ubicación de su secadora....................................... 14
Dimensiones para la instalación...............................15
Instalación en casas móviles....................................16
Desembalaje........................................................ 16
Puerta reversible...............................................16-17
Instalación eléctrica............................................... 18
Requerimientos para la puesta a tierra...................... 18
Conexiónes eléctricas - trifilares.............................   19
Conexiónes eléctricas - tetrafilares..........................  19
Conexión del gas.................................................. 20
General Instalación................................................20
Piezas de recambio................................................20

Installation

Instructions

Gas & Electric Dryer

Instrucciones

para la

Instalación

Secadora a gas y

eléctrica

 Para su seguridad, siga las instrucciones contenidas en este manual a fin de reducir a un mínimo los riesgos de incendio o

explosión o para evitar daños materiales, lesiones personales o la muerte.

-

No almacene ni utilice gasolina u otros vapores y líquidos inflamables en la proximidad de éste o de cualquier otro artefacto eléctrico.

-

QUE DEBE HACER SI PERCIBE OLOR A GAS
·

No trate de encender ningún artefacto eléctrico.

·

No toque ningún interruptor eléctrico; no use ningún teléfono en su edificio.

·

Haga salir a todos los ocupantes de la habitación, del edificio y del lugar.

·

Llame a su proveedor de gas desde el teléfono de un vecino. Siga las instrucciones del proveedor de gas.

·

Si no logra comunicarse con su proveedor de gas, llame al departamento de bomberos.

La instalación y el servicio de mantenimiento debe de realizarlos un instalador calificado, la agencia de servicios o el proveedor de gas.

Summary of Contents for FEFB9200ES0

Page 1: ...nts 2 Electrical Requirements 2 Exhaust System Requirements 3 4 Gas Supply Requirements 4 Location of Your Dryer 4 5 Rough In Dimensions 6 Mobile Home Installation 7 Unpacking 7 Reversing Door Swing 7 8 Electrical Installation 9 Grounding Requirements 9 Electrical Connections 3 wire 10 Electrical Connections 4 wire 10 Gas Connection 11 General Installation 11 Replacement Parts 11 Requerimientos de...

Page 2: ...ctors with upturned ends or closed loop connectors and marked for use with clothes dryers See ELECTRICAL CONNECTIONS for additional instructions OUTLET RECEPTACLE NEMA 10 30R 3 wire receptacle or NEMA 14 30R 4 wire receptacle to be located so the power supply cord is accessible when the dryer is in the installed position GAS Dryer CIRCUIT Individual 15 amp branch circuit fused with a 15 amp maximu...

Page 3: ...e dwelling Do not allow combustible materials for example clothing draperies curtains paper to come in contact with exhaust system The dryer MUST NOT be exhausted into a chimney a wall a ceiling or any concealed space of a building which can accumulate lint resulting in a fire hazard Exceeding the length of duct pipe or number of elbows allowed in the MAXIMUM LENGTH charts can cause an accumulatio...

Page 4: ...3 1 2 13 1 2 13 1 2 13 1 2 13 1 2 34 cm 34 cm 34 cm 34 cm 34 cm 3 3 4 3 3 4 3 3 4 3 3 4 3 3 4 9 5 cm 9 5 cm 9 5 cm 9 5 cm 9 5 cm 3 3 4 3 3 4 3 3 4 3 3 4 3 3 4 9 5 cm 9 5 cm 9 5 cm 9 5 cm 9 5 cm 2 The gas supply line should be of 1 2 inch 1 27 cm pipe 3 If codes allow flexible metal tubing may be used to connect your dryer to the gas supply line The tubing MUST be constructed of stainless steel or ...

Page 5: ...quare centimeters 3 inches 7 6 cm from bottom and top of door NOTE Under counter and stack models 0 inches 0 cm for sides rear and top This dryer MUST be exhausted outdoors 5 The following illustrations show minimum clearance dimensions for proper operation in a recess or closet installation CLOSET DOOR 60 sq inches 387 1 sq cm 15 38 1 cm 0 0 cm 60 sq inches 387 1 sq cm 1 2 54 cm 0 0 cm 0 0 cm 0 0...

Page 6: ...t 13 5 27 25 to front of cabinet 27 75 to clear knobs 28 5 to clear door handle 5 875 To base exhaust 5 0 4 375 To side exhausts To rear base exhausts 2 25 2 375 Gas supply pipe on rear of unit Electrical supply on rear of unit 123 19cm 72 39cm 12 7cm 11 12cm 14 93cm 69 22cm 70 49cm 72 39cm 5 72cm 6 03cm 68 58cm 34 29cm 36 91 44cm Dryer Installation Dimensions Free Standing Under Counter Stacked D...

Page 7: ... 2 and 3 for other important venting requirements 6 Installation MUST conform to current Manufactured Home Construction Safety Standard which is a Federal Regulation Title 24 CFR Part 32 80 or when such standard is not applicable with American National Standard for Mobile Homes The dryer is designed under ANSI Z 21 5 1 or ANSI UL2158 CAN CSA C22 2 latest editions for HOME USE only FOAM SHIPPING PA...

Page 8: ...remove the plugs Be careful to avoid scratching the paint 5 Remove the two handle screws and remove the handle by pulling straight out from door 6 Install the plugs from Step 3 into the holes left by removing the handle screws in Step 4 7 Lay the door on a flat surface and support the edges of the door to keep it from turning Apply moderate downward pressure on the lens with both hands and rotate ...

Page 9: ...rd resulting in electrical shock Do not use an aluminum wired receptacle with a copper wired power cord and plug or vice versa A chemical reaction occurs between copper and aluminum and can cause electrical shorts The proper wiring and receptacle is a copper wired power cord with a copper wired receptacle NOTE Dryers operating on 208 volt power supply will have longer drying times than operating o...

Page 10: ...ng the terminal block access cover and the strain relief mounting bracket located on the back of the dryer upper corner 2 Install a U L approved strain relief into the power cord entry hole of the mounting bracket Finger tighten the nut only at this time 3 Thread a U L approved 30 amp power cord NEMA 10 30 type SRDT through the strain relief 4 Attach the power cord neutral center wire conductor to...

Page 11: ...ructs the flow of combustion and ventilation air 5 Run the dryer through a cycle check for proper operation NOTE On gas dryers before the burner will light it is necessary for the gas line to be bled of air If the burner does not light within 45 seconds the first time the dryer is turned on the safety switch will shut the burner off If this happens turn the timer to OFF and wait 5 minutes before m...