55
SECTION 6 - ROTARY KNOB WASHER TECHNICAL DATA
If you have access to outlet receptacle...
Diagnostic Mode
No access to outlet receptacle...
Full Control R
eset
1. Unplug unit.
2. While unit is unplugged, place cycle selector
knob in presoak.
presoak
presoak
3. Position temp knob in any position except
far left position.
temp
4.
Plug in unit and within 15 seconds, complete
all of the following instructions to enter Diag-
nostic Mode.
Entering Diagnostic Mode
1. Turn temp knob all the way to the left.
Press and release the cycle selector knob.
temp
presoak
2. Turn temp knob all the way to the right.
Press and release the cycle selector knob.
temp
presoak
3.
Turn temp knob all the way to the left.
Press and release the cycle selector knob.
You will hear one long beep to indicate you
are in Diagnostic mode.
temp
presoak
4.
Turn cycle selector knob to the 12:00 o’clock
position. This is position zero for the diag-
nostics mode. Refer to the tech data sheet
for sequence of operation per the cycle
selector knob position.
position 0
NOTE
If left unattended in Diagnostic Mode for more than
5 minutes, the unit will automatically exit Diagnostic
Mode and return to normal functionality.
Exiting Diagnostics
1.
Turn the cycle selector switch to the number
1 position as defi ned by the tech data sheet
and immediately press and hold the cycle
selector knob for 10 seconds.
You will hear three short beeps to indicate
you have exited Diagnostic mode.
position 1
position 1
NOTE
You may also unplug the unit and wait 10 seconds to
exit Diagnostic Mode.
It will enter normal functionality when plugged back in.
Full Control R
eset
1. Wake up unit.
2. Place cycle selector knob in presoak.
presoak
presoak
3. Position temp knob all the way to the left.
temp
4. Press and hold cycle selector knob for 10
seconds. Release cycle selector.
presoak
5.
Turn temp knob all the way to the right.
Press and release the cycle selector knob.
You will hear three short beeps to indicate
you completed Full Control Reset. Within 15
seconds, complete all of the following instruc-
tions to enter Diagnostic Mode.
temp
presoak
Entering Diagnostic Mode
1. Turn temp knob all the way to the left.
Press and release the cycle selector knob.
temp
presoak
2. Turn temp knob all the way to the right.
Press and release the cycle selector knob.
temp
presoak
3.
Turn temp knob all the way to the left.
Press and release the cycle selector knob.
You will hear one long beep to indicate you
are in Diagnostic mode.
temp
presoak
4.
Turn cycle selector knob to the 12:00 o’clock
position. This is position zero for the diag-
nostics mode. Refer to the tech data sheet
for sequence of operation per the cycle
selector knob position.
position 0
NOTE
If left unattended in Diagnostic Mode for more than
5 minutes, the unit will automatically exit Diagnostic
Mode and return to normal functionality.
Exiting Diagnostics
1.
Turn the cycle selector switch to the number
1 position as defi ned by the tech data sheet
and immediately press and hold the cycle
selector knob for 10 seconds.
You will hear three short beeps to indicate
you have exited Diagnostic mode.
position 1
position 1
6 - 3
Summary of Contents for FAHE4044MW0
Page 2: ......
Page 7: ...7 SECTION 2 INSTALLATION INFORMATION Section 2 Installation Information 2 1 ...
Page 16: ...16 SECTION 2 INSTALLATION INFORMATION Notes 2 10 ...
Page 17: ...17 SECTION 3 CONTROL OPERATION Section 3 Control Operation 3 1 ...
Page 31: ...31 SECTION 4 COMPONENT TEAR DOWN Section 4 Component Tear Down 4 1 ...
Page 49: ...49 SECTION 5 TROUBLESHOOTING Section 5 Troubleshooting 5 1 ...
Page 53: ...53 SECTION 6 ROTARY KNOB WASHER TECHNICAL DATA Section 6 Technical Data 6 1 ...
Page 61: ...61 SECTION 6 ROTARY KNOB WASHER TECHNICAL DATA Wiring Diagram 6 9 ...
Page 69: ...69 SECTION 6 PUSH BUTTON SELECTION WASHER TECHNICAL DATA 6 17 ...
Page 70: ......
Page 71: ......
Page 72: ......