840-170-38

      

          Single Package

Vertical Air Conditioning System

B – Series

18,000 – 24,000 – 30,000 – 36,000 –

42,000 – 49,000 – 60,000 Btuh

INSTALLATION

&

OPERATION MANUAL

Summary of Contents for Vert-I-Pak VEB18K05

Page 1: ...840 170 38 Single Package Vertical Air Conditioning System B Series 18 000 24 000 30 000 36 000 42 000 49 000 60 000 Btuh INSTALLATION OPERATION MANUAL...

Page 2: ...Fan Performance 10 C Indoor Air Conditioned Supply air System 11 Indoor Fan Performance 12 2 Electrical A Grounding 12 B Power Supply 12 3 Thermostat Mounting and Wiring 13 14 A Thermostat Location 13...

Page 3: ...zes DO insulate ALL conditioned air duct system components DO NOT locate room thermostat near conditioned air diffusers DO locate thermostat on an interior wall DO check that condensate drain line dra...

Page 4: ...wer W 5000 10000 5000 10000 10000 15000 10000 15000 Heating Current A 20 8 41 6 20 8 41 6 41 6 62 4 41 6 62 4 H E A T P U M P D A T A Heating Cap Btu h 17000 17000 22000 22000 30000 30000 34000 34000...

Page 5: ...n Ckt Amps A 33 52 33 26 52 40 5 26 52 40 5 52 52 49 52 52 49 26 52 52 Power Connection Hard Wire Hard Wire Hard Wire Hard Wire Hard Wire Hard Wire P H Y S I C A L D A T A Unit Width in 38 00 38 00 38...

Page 6: ...he unit Units are available in three return air configurations front free return with disposable filter front ducted return with 1 duct flange and left side ducted return with 1 duct flange See Figure...

Page 7: ...oor Air System A Outdoor Air System A Outdoor Air System Asacompletelyself containedsystem theVert I Pakunitrequiresanadequatesupplyofoutdoorairtoexchangeheatfrom the outdoor air coil The outdoor air...

Page 8: ...8 VPBWP4 8 14 Wall Plenum Figure 6 VPBWP3 8 14 Wall Plenum Figure 5 For Models VE VHB18 VE VHB24 For Models VE VHB18 VE VHB24 VE VHB30 VE VHB36...

Page 9: ...9 VPBWP5 8 14 Wall Plenum Figure 7 VPBWP6 8 14 Wall Plenum Figure 8 For Models VE VHB42 VE VHB49 For Model VE VHB60...

Page 10: ...AIR INTAKE OUTSIDE WALL FLOOR CEILING EXHAUST OUTDOOR AIR EXHAUST INTAKE OUTSIDE WALL FLOOR OUTDOOR AIR EXHAUST OUTDOOR AIR INTAKE CEILING EXHAUST BACK OF UNIT OUTSIDE WALL Model 0 1 0 2 0 3 0 4 0 5...

Page 11: ...e front of the unit and the back side of the door The minimum net free open area required for the RA louver or grille is listed in Table 2 Return Air Options Front Free Front Free Front Free Front Fre...

Page 12: ...ound connection is made before connecting line voltage Failure to do so can result in property damage personal injury and or death Unit Wiring with VPDB1 Distribution Block 1 If wire is applied at amb...

Page 13: ...to prevent drafts that may affect thermostat performance 4 Loosely secure the thermostat to the wall with screws through the two mounting holes in the middle of the thermo stat 5 Level the thermostat...

Page 14: ...provide a field supplied secondary drain pan Always refer to local and national codes Test Run Test run in Heating Cooling and Emergency Heat mode as follows a Set fan control to ON If fan runs retur...

Page 15: ...to operate to satisfy the call for heating To minimize energy costs do not increase the HEAT mode temperature set point by more than 2 F at a time Depending on the design of your home and its ventila...

Page 16: ...mp youwillappreciateitsconstant evenheatandlowerenergyconsumption Heat Mode Operation Duringtheheatmodeofoperation frostoricemaybuildupontheoutdoor aircoilafteroperatingforextendedperiodsduring partic...

Page 17: ...doors are frequently opened and closed Laundryappliancesarebeingoperated A shower is running More than the usual number of people are present in the home More than the normal number of electric lights...

Page 18: ...it be extremely careful when handling parts or reaching into the unit REPLACE AIR FILTER A dirty air filter reduces the efficiency of your Vert I Pak and allows lint and dirt to accumulate on the indo...

Page 19: ...utdoor air exhaust paths must remain clear Check the OA exhaust frequently Keep it free of all debris snow or ice The OA intake should also be kept free of obstructions Blocking the OA exhaust or OA i...

Page 20: ...NDITIONING CO FRIEDRICH AIR CONDITIONING CO FRIEDRICH AIR CONDITIONING CO FRIEDRICH AIR CONDITIONING CO Post Office Box 1540 San Antonio Texas 78295 1540 4200 N Pan Am Expressway San Antonio Texas 782...