background image

Summary of Contents for TEC07K00

Page 1: ...STALLATION OPERATION WallMaster _Packaged Terminal Air Conditioners Packaged Terminal Heat Pumps Standard Unit Seacoast Protected Unit Remote Thermostat Unit Central Desk Control Unit _l IoHiI _ 5iIo...

Page 2: ...ostat 7 Heating Control 8 Fan Cycle Switch 8 Vent Control 8 Air Outlet Louver 9 Startup Checklist 9 Routine Maintenance 10 Appendix A Remote Thermostat 11 Appendix B Central Desk Control 15 Appendix C...

Page 3: ...ult in property damage personal injury and or death Wire Size Fuse Circuit Breaker Grounding Receptacle Wire Sizing Electrical Requirements Use ON LY wiring size recommended for single out let branch...

Page 4: ...onditioning Refrigeration May be used for 15 Amp applications if fused for 15 Amp NOTE 265 volt units are permanently connected Table 2 Recommended branch circuit wire sizes AWG Wire size Nameplate ma...

Page 5: ...door pin into the slot on the left of the front panel opening and snap it into place CAUTION To avoid breaking the door or hinge pins do not apply excessive force when installing 4 Com reseor Center...

Page 6: ...is already installed in tracks in the plastic cover Place on brackets here Two each side of front Louver Screw 9 _ Front Panel Screw g NOTE If the unit is mounted flush to the floor the service cord M...

Page 7: ...temperature at the desired setting Counterclockwise warmer Clockwise cooler Selects high speed or low speed Standard Unit Control Panel COOL HEAT FAN ONLY OFF LOW WARNER TEt4 C OLER Temperature Limiti...

Page 8: ...ergency heat position The heater will then cycle using electric resistance heat only Note that in the emergency heat position the compressor is locked out disabling both heat pump and cooling operatio...

Page 9: ...onnel ONLY Check the following _ Unit is installed in compliance with all codes and ordinances _ Circuit breakers and wire sizes are correct _ Filter is clean and in place _ All panels are in place _...

Page 10: ...and outdoor coils Paper leaves and other debris can reduce efficiency and cause serious damage to the compressor IJ Coils should be inspected periodically for buildup of lint dirt leaves other debris...

Page 11: ...ERATION Cooling Heating Fan 24V common to the thermostat Heat Damper Stage 2 Heating CONTACT MADE Durin9 call for cooling During call for heating Continuous if the slider is inthe Fan osition otherwis...

Page 12: ...n R _ 6 Locate the terminal strip on the right side of the control box Attach the thermostat subbase wires field supplied to the appropriately labeled terminals as per widng diagram on the side of the...

Page 13: ...screws provided optional Louver Screw _ Front Panel Screw NOTE If the unit is mounted flush to the floor the service cord MUST be rerouted through the side of the front panel closest to the receptacle...

Page 14: ...ires on the 240V post of the primary side of the transformer to the 208V post This will ensure correct secondary low voltages for the unit This is only required on the remote thermostat units Remote T...

Page 15: ...and place as shown Install the front panel by placing the top of the panel onto the brackets at top of the chassis Rotate the bottom into place while locating the service cord or conduit in the notch...

Page 16: ...ate receptacle Extra cord may be coiled inside front panel behind the return air louver Restore power to the unit Central Desk Control Operation Units equipped with Central Desk Control are identical...

Page 17: ...rmer is limited to maxVA per NEC 725 31 This may require multiple transformers for large installations 5 Consult the table at left for minimum wire gauges needed for any given low voltage wire run App...

Page 18: ...wise the beginning date ofthis certificate will beconsidered to be our shipment date plus sixty days Replacement parts can be new or remanufactured Replacement parts and labor are only warranted for a...

Page 19: ...Friedrich Air Conditioning Co 4200 North Pan Am Expressway RO Box 1540 San Antonio Texas 78295 1540 U S A Phone 210 357 4400 Fax 210 357 4480 rl l...

Reviews: