15
PB
SPECIFICATIONS
Electrical Data
14
Electrical Wiring for 265 Volt
Models
NOTE:
It is recommended that the PXSB subbase assembly, the
PXCJA conduit kit (or equivalent) be installed on all hardwire
units. If installing a flush-floor mounted unit, make sure the
chassis can be removed from the sleeve for service and
maintenance.
WARNING
Electrical Shock Hazard
Turn off electrical power before service
or installation.
ALL electrical connections and wiring
MUST
be installed by a qualified
electrician and conform to the National
Code and all local codes which have
jurisdiction.
Failure to do so can result in property
damage, personal injury and/or death.
Power Cord Installation
All 265V PTAC/PTHP units come with a factory installed non-LCDI
power cord for use in a subbase. If the unit is to be hard-wired refer to
the instructions below.
To install the line voltage power leads and con-
duit to chassis, follow the instructions below
and refer to Figures 25-27 on page 19. PXCJA
Conduit Kit is required with this setup.
1.
Follow the removal process of the chassis’s junction box
(Figure 25).
2.
Prepare the 265V (or 230V) power cord for connection to the chas-
sis’ power cord connector by cutting the cord to the appropriate
length (refer to Figure 26 and follow Figure 15). Power cord harness
selection shown on Table 2
Table 2
Model
Heater kW
Power Cord Kit
Voltage
Amperage
Receptacle
PDE/PDH07K
2.5
PXPC23015A
230/208
15
NEMA 6-15r
3.5
PXPC23020A (STD)
230/208
20
NEAM 6-20r
PDE/PDH09K
2.5
PXPC23015A
230/208
15
NEMA 6-15r
3.5
PXPC23020A (STD)
230/208
20
NEMA 6-20r
5.0
PXPC23030
230/208
30
NEMA 6-30r
PDE/PDH12K
2.5
PXPC23015A
230/208
15
NEMA 6-15r
3.5
PXPC23020A(STD)
230/208
20
NEMA 6-20r
5.0
PXPC23030
230/208
30
NEMA 6-30r
PDE/PDH15K
2.5
PXPC23015A
230/208
15
NEMA 6-15r
3.5
PXPC23020A
230/208
20
NEMA 6-20r
5.0
PXPC23030 (STD)
230/208
30
NEMA 6-30r
PDE/PDH07R
2.5
PXPC26515A
265
15
NEMA 7-15r
3.5
PXPC23020A (STD)
265
20
NEMA 7-20r
PDE/PDH09R
2.5
PXPC26515
265
15
NEMA 7-15r
3.5
PXPC23020A (STD)
265
20
NEMA 7-20r
5.0
PXPC26530
265
30
NEMA 7-30r
PDE/PDH12R
2.5
PXPC26515A
265
15
NEMA 7-15r
3.5
PXPC23020A (STD)
265
20
NEMA 7-20r
5.0
PXPC26530
265
30
NEMA 7-30r
PDE/PDH15R
2.5
PXPC26515A
265
15
NEMA 7-15r
3.5
PXPC26520A
265
20
NEMA 7-0r
5.0
PXPC23030 (STD)
265
30
NEMA 7-30r
203/208 Electric Heater Rating (Configuration Based on Power Cord0
POWER CORD
VOLTAGE
BRANCH CKT AMPS
MCA
WATTS
PXPCFA23015A
230/208
15
13.9
2500
PXPCFA23020A
230/208
20
19.9
3600
PXPCFA23030A
230/208
30
27.5
5000
PXPCFA26515A
265V
15
12.0
2500
PXPCFA26515A1
265V
15
7.3
1500
PXPCFA26520
265V
20
16.8
3500
PXPCFA26530
265V
25
23.8
5000
TABLE 2
MODEL
HEATER kW
Power Cord Kit
Voltage
Amperage
Receptacle
PVH09K
2.5(optional)
STD
230/208
15
NEMA 6-15r
3.5(default)
STD
230/208
20
NEMA 6-20r
PVH12K
1.5(optional)
STD
230/208
15
NEMA 6-15r
3.5(default)
STD
230/208
20
NEMA 6-20r
5.0(optional)
STD
230/208
30
NEMA 6-30r
PVH09R
2.5(optional)
STD
265/277
15
NEMA 7-15r
3.5(default)
STD
265/277
20
NEMA 7-20r
PVH12R
1.5(optional)
STD
265/277
15
NEMA 7-15r
3.5(default)
STD
265/277
20
NEMA 7-20r
5.0(optional)
STD
265/277
30
NEMA 7-30r
Summary of Contents for FRESHAIRE PVH09K3FA