background image

Dachlüfter
Roof-mounted fan
Ventilateur de toit
Dakventilator
Takfläkt
Ventilador de techo
Ventilatore da tetto

ルーフ型ファン

Montage-, Installations- und Bedienungsanleitung
Assembly and operating instructions
Notice d’emploi, d’installation et de montage
Montage-, installatie- en bedieningshandleiding
Montage-, installations- och bruksanvisning
Instrucciones de montaje, instalación y mando
Istruzioni di montaggio, installazione e uso

取扱説明書

(

組立・設置および操作マニュアル

)

3138.000

3139.100

3139.110

3140.100

3140.110

3140.140

3140.500

3140.510

Summary of Contents for Rittal 3138.000

Page 1: ...nungsanleitung Assembly and operating instructions Notice d emploi d installation et de montage Montage installatie en bedieningshandleiding Montage installations och bruksanvisning Instrucciones de m...

Page 2: ...d installation et de mon tage peut tre t l charg e depuis le site www rittal fr Opmerking De montage installatie en gebruikshandlei ding is ook te downloaden via www rittal nl Obs Montage installatio...

Page 3: ...cope of supply 6 4 Installation 6 4 1 Choosing the installation site 6 4 2 Notes on installation 6 4 2 1 General 6 4 2 2 Layout of the electronic components in the enclosure 6 4 3 Installing the roof...

Page 4: ...and servicing may only be per formed by properly trained specialists Do not obstruct the air inlet and air outlet of the roof mounted fan inside and outside the enclosure see also section 4 2 2 Layout...

Page 5: ...our class G3 filter mats installed The filter must be checked regularly de pending on the level of dust exposure and replaced as necessary 3 3 Proper use Rittal roof mounted fans were developed and de...

Page 6: ...all sides IP 54 If the enclosure has a leak unfiltered contaminated air may enter the enclosure The fan motor is a rotating component that may trans fer vibrations and oscillations Appropriate measure...

Page 7: ...Rittal roof mounted fan 7 4 Installation EN 4 3 Installing the roof mounted fan...

Page 8: ...r manufacturer or operator to ensure effec tive protection against lightning and overvoltage The limits specified in standard UL IEC EN 60335 2 40 must be observed The units are classified as overvolt...

Page 9: ...driver with a 3 5 x 0 5 mm blade Open the terminal with the screwdriver and insert the connection cable as shown in the connection dia gram Remove the screwdriver Connection Pin Function assignment L...

Page 10: ...perature monitor The life expectancy is at least 50 000 operating hours L10 40 C The roof mounted fan is therefore largely maintenance free From time to time the components may need to be cleaned usin...

Page 11: ...eded air flow with filter mats m h 417 446 446 725 759 759 700 749 841 841 Air throughput with fil ter mats and inlet filter 1 x 3243 200 m h 370 391 391 590 610 610 580 610 690 690 Fan Radial capacit...

Page 12: ...egory IP 55 IP 55 without filter mat and installation in accordance with section 4 3 Installing the roof mounted fan Installation for protection category IP 55 Accessories Packs of Spare filter mats f...

Page 13: ......

Page 14: ...ution Climate Control IT Infrastructure Software Services You can find the contact details of all Rittal companies throughout the world here www rittal com contact 3nd edition 05 2019 ID no 335 522 Dr...

Reviews: