Page 1: ...SWT 10 SE 12 GB Art no 172781 01...

Page 2: ...K mm L mm M mm SWT02 535 640 280 670 705 125 195 330 135 305 22 SWT12 675 760 420 790 825 115 195 355 160 355 22 SWT22 735 1070 480 1100 1135 110 300 415 115 430 28 1 Fan heater SWT 2 Filter SWTCF 3 A...

Page 3: ...SWT02 high 7 0 low 4 0 SWT12 high 8 0 low 5 0 SWT22 high 12 0 low 7 0 Type A mm B mm SWT02 280 640 SWT12 420 760 SWT22 480 1070 The air throw is defined as the distance in a straight angle from the fa...

Page 4: ...ch for air flow max 3A 200x105x105 RE7 5 step change over switch for air flow max 7A 247x147x145 SD20 Type RSK nr SE SD20 672 70 37 TVVS20 673 92 96 TVVS25 673 92 97 Water regulation Type Description...

Page 5: ...230 V SD20 TVVS20 25 TKS16 A B 2 4 2o 6 7 5 t C 9 1 2 3 KRT 1 2 M 3 4 5 6 7 8 SWT N Blue Black Brown L N 230 V SD20 TVVS20 25 9 1 2 M L N 230 V 3 4 5 6 7 8 SWT N Blue Black Brown 9 SWT 5 Control by t...

Page 6: ...2 M 3 4 5 6 7 8 SWT N Blue Black Brown L N 230 V 2 4 5 1 3 CB20 7 9 1 2 M 3 4 5 6 7 8 SWT N Blue Black Brown N RE1 5 7 N L N 230 V 9 SWT 6 2 step control of airflow only 5 step control of airflow onl...

Page 7: ...L N 230 V SD20 TVVS20 25 2 4 5 1 3 CB20 7 TKS16 A B 2 4 2o 6 7 5 t C 9 1 2 3 KRT 1 2 M 3 4 5 6 7 8 SWT N Blue Black Brown L N 230 V SD20 TVVS20 25 N RE1 5 7 N 9 1 2 M 3 4 5 6 7 8 SWT N Blue Black Bro...

Page 8: ...48 60 34 30 4 5 7 5 7 12 Type Water 5 volume 5 l Voltage 6 V Amperage 7 A LxWxH 8 mm Weight 9 kg RSK SE NRF NO SWT02 1 2 230V 0 4 705x535x330 19 672 67 03 850 23 11 SWT12 1 7 230V 0 6 825x625x355 26 6...

Page 9: ...Pres sure drop kPa Output kW Air temp out C Water flow l s Pres sure drop kPa SWT02 max 0 31 7 5 30 0 09 4 9 6 4 40 0 08 3 8 5 3 34 0 06 2 7 min 0 19 5 4 33 0 06 2 8 4 6 34 0 06 2 1 3 8 36 0 05 1 5 SW...

Page 10: ...ndlas ner anv nd takpendlar till l mplig niv Borrmall och minavst nd till v gg se fig 2 och fig 3 Om takkonstruktionen r svag m ste den f rst rkas s att en s ker installation uppn s F r vikter p varje...

Page 11: ...per r och reng ring vid behov Vid inspektion och service ska str mf rs rjningen alltid brytas Reng ring av fl kt G r v rmaren sp nningsl s Lossa excenterl sen p fl ktpl ten och l t den h nga ner Bl s...

Page 12: ...s Secure the fan heater to the ceiling with four screws through the brackets Drop rods are used when mounting at a distance from ceiling For drilling template see fig 2 and fig 3 If the ceiling struct...

Page 13: ...g inspection the power supply must always be disconnected Cleaning the fan Cleaning intervals of the fan is due to filter if any and air quality To ensure performance and reliability of the unit inspe...

Page 14: ......

Page 15: ......

Page 16: ...office Frico AB Tel 46 31 336 86 00 Box 102 SE 433 22 Partille mailbox frico se Sweden www frico se For latest updated information and information about your local contact www frico se 2014 03 27 HH...