background image

Vos vins seront bien gardés

Installation Manual

MPC Genesis - Vintage

GB-NT-MPC-0314

Pour la CAVE

Vos vins seron

Po

ur

ur

ur

l

l

 l

l

a

a

a

CA

CA

CA

CA

VE

VE

VE

VE

Pour la CAVE

Pour l

a

CA

CA

VE

Pour la CAVE

R

"FRIAX industrie" in a constant endeavour to improve its products reserves the right to change 
any information contained in this leaflet without prior warning

Summary of Contents for MPC Genesis 30

Page 1: ...14 Pour la CAVE Vos vins seron Pour ur ur l l l la a a a CA CA CA CAVE VE VE VE Pour la CAVE Pour la CA CAVE Pour la CAVE R FRIAX industrie in a constant endeavour to improve its products reserves the...

Page 2: ...regula on box These elements are interconnected by a refrigerant pipe and an electrical connec on At the delivery you must find in your package your Monobloc the installa on manual and the accessorie...

Page 3: ...ar side 2m 2m Refrigerant R134A R134A nominal outside temperature 32 C 32 C 9 15 C 9 15 C Weight 45 kg 49 kg 3 58 A Current cooling mode 2 41 A 3 24 A 365 m3 h 310 m3 h Temperature se ng range Airflow...

Page 4: ...on MPC 30 Genesis MPC 48 Genesis MPC 30 Vintage MPC 48 Vintage HGR S S CWR S S S S KCH O O S S KPC S S S S KFG O O O O KLP O O O O RSF KBPL KGDD KGS S S S S O O O O O O O O O O O O RC s s S S Monoblo...

Page 5: ...he drain siphon Humidifier water supply 20 27 male on vintage models Principle of opera on Power fuse holder o switch inside cave Evaporator outside cellar condenser Ext rieur 32 C Cave 12 C Condenseu...

Page 6: ...tural and mechanical ven la on should be avoided in the cellar Ensure that the hot air is discharged into a ven la ted and sheltered room Check the strength of the wall on which the unit is a ached Re...

Page 7: ...onobloc body is adapted to be fixed at 5 di erent depths of recesses Dans certaines posi ons et en fonc on du support il peut tre n cessaire d ajouter des renforts pour viter que l appareil ne bascule...

Page 8: ...pply to the humidifier HGR for Vintage models 2 Connect the drain 1 Connect the siphon supplied accessory directly on the flow of the unit elbow Thanks to the use of the cap seal the connec on between...

Page 9: ...control could be installed in any room Its maximum range is 100m in a completely open area This distance could be extremly reduced from the thick walls and the loca on of the cellar It is possible to...

Page 10: ...probe 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Parameter number Setup mode RF Transmission Temperature or humidity option Remote battery charge level C F or humidity unit indicator Speed condenso...

Page 11: ...stalla on It may however be shortened see Step III Ge ng Started This standby mode does not preclude performing the steps I and II 2 Remove the black protec ve cap bu on 1 3 hold the bu on for 6 secon...

Page 12: ...creens with OK OK confirm with Change the value with or Access to menu Parameters Screens Manipulations See below the value set according to the device Login with Shorten the wai ng period hold Start...

Page 13: ...lashing Displays the current value of the setpoint tempera ture Displays the current value of the set point humidity Only for version Vintage Displays the value of setpoint desired humidity Only for v...

Page 14: ...an returns to its normal speed Manipula on bu ons no longer possible to change the se ngs Bu ons are accessible to change the se ngs The screen turns o a er a few seconds The appliance con nues to ope...

Page 15: ...play on 24 Access to menu Parameters Screens Manipulations OK OK confirm with Change the value with or Login with OK OK confirm with Change the value with or Login with OK OK confirm with OK confirm w...

Page 16: ...rameter is set to 0 at the factory It may be modified only in the case where there would be a gap between the moisture displayed and the actual humidity of the cellar Only model Vintage r elle cellar...

Page 17: ...Condenser T sensor Low temperature High temperature sensor broken down High temperature Overheating Fan broken down Fan broken down Type of error Two types of errors may appear on the wireless remote...

Page 18: ...maintenance work switch o the power supply to the main circuit breaker Maintenance of the condenser hot side Remove the front cover using an Allen wrench to access the condenser coil air Use a vacuum...

Page 19: ...GT L N T HGR ou Sur version Vintage GND PWM2 TAC2 bleu jaune blanc L N L N EVF CDF RC L N Compressor Fan Heater Wiring diagram Blue Blue Black Black on Vintage model blue yellow white blue yellow whi...

Page 20: ...Site web www friax fr Boite mail friax fr info R INDUSTRIE 231 233 Rue de la Prairie F 73420 Voglans D couvrez notre de cave de rangement pour la cave site web www visiorack com...

Reviews: