Fri-Jado 120-2-C FS User Manual Download Page 10

MCC 

 Cold / Ambient

 

EU 

10/40 

2. 

DESCRIPTION OF THE UNIT 

2.1 

Technical description 

The panels are made of galvanized steel plating, stainless steel or aluminium.  Some of the visible 
internal and external parts have been provided with a powder coating.  The glass used is tempered 
or  layered.    The  unit  can  be  moved  by  means  of  a  pallet  truck.    The  controls  for  operating  the 
appliance have been mounted on the operator side of the unit.  The product contact parts are made 
of stainless steel AISI 304 or AISI 430 and tempered glass.  
 

Cold Units:

 

Cooling is achieved by means of a thermostatic temperature-controlled cold airflow.  The cold air is 
passed via the back and shelves over the products.  Self-serve models have an additional set of 
fans mounted in the top to create a stable air curtain on the open side of the cabinet to minimize the 
infiltration  of  warm  ambient  air.    The  air  on  the  front  side  passes  through  the  suction  grid  in  the 
bottom of the unit.  The MCC Cold unit is available in a 2, 3 and 4 level execution. 
The temperature of the airflow is controlled electronically.  The electronically-controlled thermostat 
is  factory  programmed  for  the  correct  temperature.    The  set  temperature  can  be  changed  from 
-1

º

C to +5

º

C.   

The units can be connected to a fixed drainage system or an optional evaporation tray to evacuate 
condensation water.  One LED-module per level provides for lighting of the products.  Lighting will 
automatically go on when switching on the cooling.  Self-serve models can be fitted with an option 
night curtain.  

For the Self-serve models there are two user variants; a solid back version and a pass 

through version which allows the user to (re)fill products via the back side. 

 

 

Ambient Units: 

The  MCC  Ambient  unit  is  available  in  a  2,  3  and  4  level  execution.    One  LED-module  per  level 
provides for lighting of the products.

 

 

2.2 

Intended use 

Self-serve models (SS models) have been designed solely to keep packaged products cold and/or 
to display them.  Full serve models can be used for unpacked foodstuff as well.  Any other use will 
not be regarded as intended use. 
The manufacturer accepts no liability whatsoever for loss or injury caused by failing to strictly adhere 
to the safety guidelines and instructions in this manual or due to carelessness during installation, 
use, maintenance and repair of the unit referred to in this manual and any of its accessories. 
 
Use the unit in perfect technical condition only. 
 

 

2.3 

Accessories 

Your unit contains the following standard accessories: 

  User manual, 

  Plinth set, 

  Front doors (when applicable). 

 
For optional accessories see 

www.frijado.com

. 

 

 

Summary of Contents for 120-2-C FS

Page 1: ...MCC Cold Ambient EU EN Original Instruction 9124736 2207 USER MANUAL Modular Convenience Counter Cold Modular Convenience Counter Ambient WARNING Read the instructions before using the machine...

Page 2: ...al As a result of constant commitment to improvement it may happen that your unit deviates in detail from what is described in this manual For this reason the given instructions are only a guideline f...

Page 3: ...ended use 10 2 3 Accessories 10 3 INSTALLATION AND FIRST USE 11 3 1 Unpacking the unit 11 3 1 1 Unpacking the front doors optional 12 3 2 Installation and positioning 12 3 2 1 Level the unit 13 3 2 2...

Page 4: ...CC Cold Ambient EU 4 40 5 5 Cleaning interior bottom 30 5 6 Cleaning the condenser Self Contained Cold units 30 6 MALFUNCTIONS AND SERVICE 31 6 1 Replace the mains cord 31 7 TECHNICAL SPECIFICATIONS 3...

Page 5: ...ion plate can be found on the outside of the machine and contains the following data Name of the supplier or the manufacturer Model Serial number Year of construction Voltage Frequency Power consumpti...

Page 6: ...lways use the brakes on both front wheels when applicable 1 4 1 General The user of the unit will be fully responsible for abiding the locally prevailing safety rules and regulations The unit may be o...

Page 7: ...herein R290 WARNING The propane refrigerant is highly flammable All safety precautions must be followed Keep all ventilation openings in the housing of the appliance or in the installation unobstructe...

Page 8: ...devices or other components except piping between the motor compressor and the pressure relief device that could introduce a pressure drop The pressure relief device shall be mounted so that any refri...

Page 9: ...your unit is included In case of malfunctions you can contact your dealer service agent Make sure you have the following data available Model Serial number This data can be found on the identification...

Page 10: ...hanged from 1 C to 5 C The units can be connected to a fixed drainage system or an optional evaporation tray to evacuate condensation water One LED module per level provides for lighting of the produc...

Page 11: ...unit In case of damage store the packing material and contact the transporter within fifteen working days after receiving the goods 3 1 Unpacking the unit 1 Unpack the unit as initiated on the unpacki...

Page 12: ...Place the unit level on a sufficiently sturdy floor Keep the weight of the unit in mind Use a levelling instrument to level the unit by adjusting the unit s legs Be sure that the personnel have suffi...

Page 13: ...5 mm 3 2 2 Mounting the plinths Place the rear plinth by attaching it to both rear adjustable legs using its two clamps Insert the pegs of both side plinths into the slots of the rear plinth Secure th...

Page 14: ...and with the warning sticker above the handle Position the door over the bottom profile and place a plastic spacer between the bottom profile and the collar bearing Insert the retaining bolt from the...

Page 15: ...rails for full serve models can be mounted on the air inlet grill and on the glass shelves Self serve models are supplied with price rails as standard Refer to installation manual 3 3 Drop in units Fo...

Page 16: ...in the example below to change from a horizontal to an angled position Reverse the steps to change to a horizontal position from an angled position 1 Carefully lift the glass shelf out of its side su...

Page 17: ...ture Please note that the rear level is supposed to be located at an equal or higher level than the LED armature 6 Place the glass shelf back onto its supports 3 5 Plateau Options The bottom presentat...

Page 18: ...rts at the front and the back to the desired positions Place the plateaus back in the unit 3 6 First use Before starting to use the unit clean the inside thoroughly with mild detergent and water After...

Page 19: ...ng on the unit Switch the cooling on by means of the temperature controller Let the unit cool for approx 30 minutes Loading the unit Only load products of which the temperature is maximum 4 C The maxi...

Page 20: ...d until you find the folder SET 3 Press SET to view the current setpoint value 4 Change the setpoint value using and within 15 seconds 5 To confirm the value press SET or or let a timeout occur 15 sec...

Page 21: ...e unit In order to avoid temperature rise of the products store them in another cooling unit Switch the cooling and lighting off using the corresponding switches 4 1 2 1 Danfoss Temperature Controller...

Page 22: ...ith the factory settings The indication will light when the cooling is active Adjusting the SET Temperature 1 Press Set until the display shows the current temperature setpoint flashing 2 Change the s...

Page 23: ...estoring the gloss Weekly Glass panes Clean see section 5 4 Weekly Interior bottom Clean see section 5 5 Weekly Condenser Clean see section 5 6 Monthly 5 2 Daily Cleaning Clean the inside of the unit...

Page 24: ...nd hold up the top glass pane throughout the process The air guide pane is laid up freely and somewhat flexible and can as such easily be removed from its support on the rear by applying a light amoun...

Page 25: ...t leave it standing upright without being supported by both guide rails or holding it It is recommended to only move the pane to such an extent that the pane areas next to the support columns can be c...

Page 26: ...orward do not drop whilst holding the top glass Lower the top glass back in place Clean the front glass Closing Lift and hold the top glass whilst closing the front glass A positive snap will make sur...

Page 27: ...its climate Cleaning the sliding doors is therefore recommended during off hours Follow the following steps to access the inner sides of the sliding doors and the rear of the shelves for cleaning Slid...

Page 28: ...until the innermost door s slot aligns with the guiding pin NOTE The outermost door should still be in its rotated position Turn the innermost door outwards as well to clean it Follow the above steps...

Page 29: ...MCC Cold Ambient EU 29 40 Cleaning front door s optional Clean the outside of the front doors Open the front doors and clean the inside of the doors in the same way as the outside...

Page 30: ...nser Self Contained Cold units WARNING Cleaning of the condenser must be performed by qualified persons and in a well ventilated environment Unscrew the condenser cover and open it WARNING Do not dama...

Page 31: ...meter cupboard Are all the switches in the correct position Item Malfunction Possible action Unit Unit does not work Check the power supply Are all switches in the correct position Unit Display shows...

Page 32: ...25 C 60 RH 3 25 C 60 RH 3 25 C 60 RH Minimum room floor area 8 13 m2 10 53 m2 12 92 m2 Refrigerant2 R290 R290 R290 Refrigerant charge 170 g 220 g 270 g Model MCC 90 3 C SS 90 4 C SS 120 3 C SS 120 4 C...

Page 33: ...m2 Refrigerant4 R290 R290 R290 Refrigerant charge 170 g 220 g 270 g Model MCC 90 3 C FS 90 4 C FS 120 3 C FS 120 4 C FS 150 3 C FS 150 4 C FS Approved for EU EU EU Width 900 mm 1200 mm 1500 mm Depth...

Page 34: ...CO2 R744 CO2 Circuit volume 1 58 dm3 2 22 dm3 2 83 dm3 Model MCC 90 3 C SS 90 4 C SS 120 3 C SS 120 4 C SS 150 3 C SS 150 4 C SS Approved for EU EU EU Width 900 mm 1200 mm 1500 mm Depth 750 mm 750 mm...

Page 35: ...2 R744 CO2 Circuit volume 1 58 dm3 2 22 dm3 2 83 dm3 Model MCC 90 3 C FS 90 4 C FS 120 3 C FS 120 4 C FS 150 3 C FS 150 4 C FS Approved for EU EU EU Width 900 mm 1200 mm 1500 mm Depth 750 mm 750 mm 75...

Page 36: ...rthed plug 16A 2 pole earthed plug 16A Length power cord approx 1 5 m 1 5 m 1 5 m 1 5 m Model MCC 60 3 A 60 4 A 90 3 A 90 4 A 120 3 A 120 4 A 150 3 A 150 4 A Approved for EU EU EU EU Width 600 mm 900...

Page 37: ...MCC Cold Ambient EU 37 40 Notes...

Page 38: ...MCC Cold Ambient EU 38 40 Notes...

Page 39: ...MCC Cold Ambient EU 39 40 Notes...

Page 40: ...Cold Ambient EU 40 40 Fri Jado B V Blauwhekken 2 4751 XD Oud Gastel The Netherlands Tel 31 0 76 50 85 400 Fri Jado Inc 1401 Davey Road Suite 100 Woodridge IL 60517 USA Tel 1 630 633 7950 www frijado...

Reviews: