995066 - Revision A
Page 21 of 41
9.4 – Attachment Bracket
In this section it will explain the correct procedure on removing and reinstalling the
Attachment Bracket for servicing procedures or replacement.
Removal
Step 1 – Remove the Battery (refer to section 9.1)
Step 2 – Remove the Cables/Leads from the Control Box (refer to section 9.2)
Step 3 – Remove the Control Box (refer to section 9.3)
Step 4 – Using a 3mm Allen Key and 8mm Spanner, remove the three circled screws to
release the Attachment Bracket.
Refitting / Replacement
Step 5 - Refitting is a reversal of the removal process noting the following points:
A)
Ensure the Bracket is attached in the correct orientation, use the image above for
guidance.