![FreeWave FGR2-IO-IOE User Manual And Reference Manual Download Page 88](http://html1.mh-extra.com/html/freewave/fgr2-io-ioe/fgr2-io-ioe_user-manual-and-reference-manual_2331115088.webp)
5. Installing and Wiring Components
5.3.3 Terminal Port Mappings in
Tool Suite
1. Verify that:
a. both the I/O Master and the I/O Slave are configured as described in the other
sections in this manual.
b. the I/O Master can connect to the I/O Slave.
2. Using
Tool Suite
, connect to the I/O Master and select the I/O Settings tab.
3. Map the terminal ports in the
I/O Settings
tab in the I/O Master to the I/O Slave using:
l
Analog Out 1
to
Slave AI1
for the tubing sensor.
l
Analog Out 2
to
Slave AI2
for the casing sensor.
l
Digital Out 1
to
Slave DI1
for the solenoid valve.
4. Send the settings to the radio:
Note
: The I/O Slave is listed by serial number.
This example has only one I/O Slave in the network with only one Slave is listed in the port
selection fields.
If there were additional I/O Slaves in the network, each Slave the I/O Master is connected to
would appear in the list.
5. In
Tool Suite
, select the I/O Slave and select the
Wire Replacement
tab.
6. Set
Digital Out 1
to
Master DI1
for the solenoid valve.
Page 88 of 131