background image

9

TOWER SYSTEM

  TWR-K53N512 Jumper Configurations

Jumper

Position

Function

J1

Open

R71 to ADC1_DM1

J3

Open

FlexBus Latch OE

J4

2-3

Medical Connector Pin 4 Function

J11

1-2

External Oscillator Selection

J15

Connected

Core VDD

J17

Connected

Oscillator Power Enable

J18

Connected

USB0_VBUS Voltage In

J24

1-2

SYS_PWR Select

J28

Open

Disable JM60 Bootloader

J34

Open

Oscillator OE Control

MED-SPI Jumper Options 

The following is a list of jumper options. The default installed jumper settings are 
shown in white text within the green boxes.

Summary of Contents for MED-SPI

Page 1: ...Quick Start Guide MED SPI Spirometry Plug in Board TOWER SYSTEM...

Page 2: ...ment platform that enables rapid prototyping and tool re use through reconfigurable hardware Elevate your design to the next level with this industrial powerhouse by building your Tower System today Q...

Page 3: ...lication It includes the MPXV7025DP differential pressure sensor which allows calibrated pressure and air flow measurements ideal for medical respiratory monitoring devices Features Tower System compa...

Page 4: ...is quick start guide you will learn how to set up the MED SPI and Tower System and run the included demonstrated software For more detailed infomation review the user manual at freescale com healthcar...

Page 5: ...m the computer to the USB port on the TWR K53N512 board Wait for drivers to install 7 Download the Application Note Go to freescale com and conduct a parametric search for AN4325 Download AN4325SW zip...

Page 6: ...Install the Medical GUI software It can be downloaded from freescale com Note Make sure you have already installed Java JDK on your computer Look for JDK folder in C Program Files Java 11 Change the...

Page 7: ...ivers for JM CDC Demo If the driver is not installed automatically open Device Manager and install drivers for JM CDC Demo Drivers can be found here 32 bit version C Freescale Medical GUI Drivers x32...

Page 8: ...he tube in your mouth 2 Inhale as much air as you can 3 Without taking the tube out of your mouth exhale as hard and fast as possible 4 Click again on the SPI section 15 Attach the Hose Attach the hos...

Page 9: ...1 2 External Oscillator Selection J15 Connected Core VDD J17 Connected Oscillator Power Enable J18 Connected USB0_VBUS Voltage In J24 1 2 SYS_PWR Select J28 Open Disable JM60 Bootloader J34 Open Oscil...

Page 10: ...Quick Start Guide 10 TWR SER Jumper Configurations Jumper Position Function J10 1 2 VBDEV Source J16 3 4 USB Mode Select J2 1 2 CLK_SEL Source...

Page 11: ...11 TOWER SYSTEM...

Page 12: ...eir respective owners 2013 Freescale Semiconductor Inc Document Number MEDSPIQSG REV 0 For more information visit freescale com Tower Join the online Tower community at towergeeks org Visit freescale...

Reviews: