FlexRay Module (FLEXRAYV4)
MFR4310 Reference Manual, Rev. 2
Freescale Semiconductor
89
3.3.2.16
Channel A Status Error Counter Register (CASERCR)
This register provides the channel status error counter for channel A. The protocol engine generates a slot
status vector for each static slot, each dynamic slot, the symbol window, and the NIT. The slot status vector
contains the four protocol related error indicator bits
vSS!SyntaxError, vSS!ContentError, vSS!BViolation
,
and
vSS!TxConflict
. The FlexRay module increments the status error counter by 1 if, for a slot or segment,
at least one error indicator bit is set to 1. The counter wraps around after it has reached the maximum value.
For more information on slot status monitoring, see
Section 3.4.18, “Slot Status Monitoring
”.
3.3.2.17
Channel B Status Error Counter Register (CBSERCR)
This register provides the channel status error counter for channel B. The protocol engine generates a slot
status vector for each static slot, each dynamic slot, the symbol window, and the NIT. The slot status vector
contains the four protocol related error indicator bits
vSS!SyntaxError
,
vSS!ContentError
,
vSS!BViolation
,
and
vSS!TxConflict
. The FlexRay module increments the status error counter by 1 if, for a slot or segment,
at least one error indicator bit is set to 1. The counter wraps around after it has reached the maximum value.
For more information on slot status monitoring see
Section 3.4.18, “Slot Status Monitoring
0x0024
Additional Reset: RUN Command
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R
STATUS_ERR_CNT
W
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Figure 3-15. Channel A Status Error Counter Register (CASERCR)
Table 3-23. CASERCR Field Descriptions
Field
Description
15–0
STATUS_ERR_CNT
Channel Status Error Counter — This field provides the current value channel status error counter. The
counter value is updated within the first macrotick of the following slot or segment.
0x0026
Additional Reset: RUN Command
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R
STATUS_ERR_CNT
W
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Figure 3-16. Channel B Status Error Counter Register (CBSERCR)
Table 3-24. CBSERCR Field Descriptions
Field
Description
15–0
STATUS_ERR_CNT
Channel Status Error Counter — This field provides the current channel status error count. The counter
value is updated within the first macrotick of the following slot or segment.
Summary of Contents for FlexRay MFR4310
Page 2: ......
Page 3: ...MFR4310 Reference Manual MFR4310RM Rev 2 03 2008...
Page 6: ...MFR4310 Reference Manual Rev 2 6 Freescale Semiconductor...
Page 12: ...MFR4310 Reference Manual Rev 2 12 Freescale Semiconductor Section Number Title Page...
Page 24: ...MFR4310 Reference Manual Rev 2 24 Freescale Semiconductor Table Number Title Page...
Page 28: ...Introduction MFR4310 Reference Manual Rev 2 28 Freescale Semiconductor...
Page 58: ...Device Overview MFR4310 Reference Manual Rev 2 58 Freescale Semiconductor...
Page 234: ...Clocks and Reset Generator CRG MFR4310 Reference Manual Rev 2 234 Freescale Semiconductor...
Page 260: ...Package Information MFR4310 Reference Manual Rev 2 260 Freescale Semiconductor...
Page 267: ......