5.2
Maintenance Port Interface (MPI) Hardware Configuration
5.2.1 Terminal Program Interface
The following 5.2.1 sub-sections describe interfacing directly to the MPI using a terminal
interface program on a PC, like “Tera Term,” to enter MPI commands. The interfaces discussed
earlier in sections 2.5.10, 2.5.10.1, 2.5.10.2 (Wi-Fi MPI, Serial-to-USB, Ethernet) can be used to
interface to the PC.
“Tera Term” should be installed on the PC and a MPI connection made via serial port or Wi-Fi
depending on the interface device used.
The terminal setup should be set to:
•
Local Echo
– checked
Figure 8: Tera Term Terminal Setup
5.2.1.1 Terminal MPI Network Connection Settings
A Network connection to the FDL-DB series systems can be made on the PC or Android tablet
running the ADS-B MPI app. The ty
pical “Tera Term” TCP settings for the Network connections
are:
Table 21. Tera Term Network Connection Settings
Setting
Remote Network Server
Port 1
Remote Network Server
Port 2
TELNET
Host Address
User configurable
User configurable
DHCP (default)
OR User defined Static
TCP Port (default)
OR UDP
44000 (default) OR User
configurable
55000 (Default) OR User
configurable
23
Service
Other
Telnet
Protocol
UNSPEC