AutoTune for Motorola APX Series Radios User Guide
14
4.9. Rx VLIF DCA Phase Error
RF Control Port
Frequency
Modulation
Generate
RF IN/OUT, RF GEN OUT Test Frequency FM
Table 4-19. Analyzer Configuration for Rx VLIF DCA Phase Error alignment
4.9.1. Alignment
Note
: This alignment is only performed for APX 900 portable models.
The Rx Front End Filter adjusts the radio’s Rx VLIF DCA Phase Error.
The radio is placed into Test Mode at the first Rx Test Frequency. The analyzer
generates a CW signal at -15 dBm into the radio. The radio softpot is then auto-aligned.
This adjustment is performed for each Rx Test Frequency available. The results for
each Rx Test Frequency are written to the test log file.
Name
Description
Result
Pass or Fail. Pass unless radio reports an error.
Frequency
Test Frequency
VLIF Phase Error VLIF Phase Error parameters
Table 4-20. Rx VLIF DCA Phase Error alignment results
See Rx Analog Sensitivity (SINAD) for alignment verification test.