AutoTune for Motorola APX Series Radios User Guide
12
4.7. Rx Front End Filter
RF Control Port
Frequency
Modulation
Generate
RF IN/OUT, RF GEN OUT Test Frequency FM
Table 4-15. Analyzer Configuration for Rx Front End Filter alignment
4.7.1. Alignment
Note: This alignment is only performed for UHF R1 and UHF R2 band models.
The Rx Front End Filter adjusts the radio’s RF front end for optimal selectivity and
sensitivity.
The radio is placed into Test Mode at the first Rx Test Frequency. Depending on the
radio model under test, the analyzer generates a CW signal at -90 dBm or a 1 kHz
modulation tone at 60% rated channel deviation at -80 dBm. The radio softpot is then
auto-aligned. This adjustment is performed for each Rx Test Frequency. The results for
each Rx Test Frequency are written to the test log file.
Name
Description
Result
Pass or Fail. Pass unless radio reports an error.
Frequency
Test Frequency
Old Softpot Original radio softpot setting
New Softpot Radio softpot setting after alignment
Table 4-16. Rx Front End Filter alignment results
See Rx Analog Sensitivity (SINAD) for alignment verification test.