FR500D Series Special Purpose Inverter for Elevator
- 16 -
Chapter 3 Function Parameters
3.1 The Basic Function Parameters
Table 3-1 Basic Function Parameters
Function
Code
Name
Descriptions
Default
Value
At
tri
bu
te
Group F00: System Parameters
F00.00
User Password
0
~
65535
0
×
F00.02
Parameter Protection
0: All parameter programmable
0
×
1: Only F00.02 and this parameter
programmable
F00.04
Default Value Control
0: No operation
0
×
1: Restore all parameters to factory
default
(excluding motor parameters)
2: Clear fault record
3: Back up current user parameters
4: Restore user backup parameters
5: Restore factory default
(include motor parameter)
6: Power consumption zero
clearing(U00.35)
F00.05
Copy of Parameters
0: No operation
0
×
1: Upload parameter
2: Download parameter (excluding
motor parameters)
3: Download parameter (including
motor parameters)
F00.08
Motor control mode
0: Voltage/Frequency (V/F)
control
1
×
1:Sensor-less vector control 1
2: Sensor-less vector control 2
3:Close loop vector control with PG
card
F00.13
Carrier frequency
0.700
~
16.000kHz
Model
defined
△
F00.18
Fan control
0: Run at power-on
1
×
1: Fan working during running
F00.20
Inverter rated power
4
~
75kW
Model
defined
⊙
F00.21
Inverter rated voltage
380V
Model
defined
⊙
F00.22
Inverter rated current
11~157A
Model
defined
⊙
F00.23
Software version
0.00
~
655.35
Model
defined
⊙
F00.24
Dealer password
0
~
65535
0
×