![FRC Turbofoam TFC100 User Manual Download Page 67](http://html1.mh-extra.com/html/frc/turbofoam-tfc100/turbofoam-tfc100_user-manual_2329200067.webp)
TFC100 Rev180215
67
12-Pin Connector/Cable
Pin/Wire
Description
1/Red
Supply Power 12/24 VDC
2/Black
Supply Ground
3/Red
N/A
4/White N/A
5/Black N/A
6/Red
N/A
7/White
FRC Datalink (+)
8/Green
FRC Datalink (–)
9/Black N/A
10/Red N/A
11 N/A
12 N/A
Optional Remote Control Module
Figure W10. Optional Remote Control Module Wiring
NOTE
: For either the TFC100 or TFC200/300/400—
Connect pin 7 and pin 8 to the primary control module
Remote Control Module
TFC200/300/400
Rear View
DC
Power
FRC
Datalink
Cable
FRC
Datalink
Cable
Remote Control Module
TFC100
DC
Power
USB
Access
Port
*
USB
Access
Port
*
*NOTE:
If opened, USB access port plug must be
tightened to a torque of 8-10 in-lbs. Exceeding this torque
value can result in damage to its water seal capability.