Figure W3. Foam Pump Control Wiring
Foam Pump Control
The foam pump control is a part of the foam pump assembly. The box houses the electronics that control the
motor. The power for the electronics is provided over the four wire cable from the control module. Motor power
is provided over separate DC supply cables. Refer to table for recommended wire size.
The rubber terminal covers for the DC supply power should be installed with the opening down to prevent
water from collecting in the cap.
Note:
The rubber terminal covers should be installed
with the opening down to prevent water from collecting
in the cap. Ensure that the rib on the cap snaps into the
groove in the terminal.
Pin 1
DC Supply
Power Input
To
Motor
Note:
The DC supply cables should
be routed down and under the motor.
Pump Size in GPM (LPM)
1.6 (6.06)
2.1 (7.95)
2.6 (9.84)
3.5 (13.25)
5.0 (18.93)
6.2 (23.47)
6.5 (24.61)
Motor Horse Power
1/3
1
1/2
3/4
1
1
1
DC Voltage
12 24
12 24
12 24
12 24
12 24
12
24
Maximum Current (AMPS)
36 18
90 45
50 25
68 34
78 39
90
45
Wire Size (AWG)
[Recommended for up to a
10 foot run.]
6 6
2 4
4 6
2 4
2 4
2
4
Table 10. Foam Pump DC Supply Power Input Wire Size
– +
+ –
12-Pin Connector/Cable
Pin/Wire
Description
1/Red
Supply Power
2/Black Ground
3/White
FRC Datalink (+)
4/Green
FRC Datalink (–)
5/Red
Close Valve (+)
6/Black/Brown Ground
7/White
Close Limit Switch
8/Blue
Open Limit Switch
9/Green
Open Valve (+)
10
+ DC AUX Out (3 A)
11/Red
RPM Sensor Signal
12/Black
RPM Sensor Ground
Notes:
- Supply power for electronics is provided by the control module.
- Pins 5-9 are used when the electric flush valve is installed.
- Pin 10 oDC voltage when the foam concentrate pump
is operating. It is capable of driving a 3 amp load.
The output from pin 10 is commonly used to open a CAFS
valve. (No output during flush operations.)
Summary of Contents for Turbofoam TFC100
Page 69: ...TFC100 Rev180215 69 CONTROL MODULES Figure P1 TurboFoam Control Modules 6 7 5 4 3 2 1 ...
Page 81: ...TFC100 Rev180215 81 MANUAL ABF SELECTOR Figure P7 Manual ABF Selector 9 8 6 5 4 3 2 1 7 ...
Page 85: ...TFC100 Rev180215 85 NOTES ...
Page 86: ...TFC100 Rev180215 86 NOTES ...
Page 87: ...TFC100 Rev180215 87 NOTES ...
Page 88: ...TFC100 Rev180215 88 ...