FRC Flush Mount ICA400 Series Manual Download Page 1

ICA100 Rev171109

1

INTERCOM

AMBULANCE/RESCUE VEHICLE

 MODEL ICA100

SURFACE MOUNT SERIES

MODELS ICA200, ICA300

FLUSH MOUNT SERIES

MODELS ICA400, ICA500

Document Number:

XE-ICA1PM-R0A

FIRE RESEARCH CORPORATION

www.fireresearch.com

26 Southern Blvd., Nesconset, NY 11767

TEL  631.724.8888   FAX  631.360.9727   TOLL FREE  1.800.645.0074

ICA200/300

ICA400/500

ICA100

Summary of Contents for Flush Mount ICA400 Series

Page 1: ... MOUNT SERIES MODELS ICA200 ICA300 FLUSH MOUNT SERIES MODELS ICA400 ICA500 Document Number XE ICA1PM R0A FIRE RESEARCH CORPORATION www fireresearch com 26 Southern Blvd Nesconset NY 11767 TEL 631 724 8888 FAX 631 360 9727 TOLL FREE 1 800 645 0074 ICA200 300 ICA400 500 ICA100 ...

Page 2: ...SERIES INSTALLATION 12 Pre Installation 12 Install Remote Station 12 Install Master Station s 12 OPERATION 16 Basic Two Way System 16 Basic Three Way System 16 System Options 16 Operational Check 17 List of Tables Table 1 Intercom Specifications 3 List of Figures Figure 1 ICA100 Mounting Dimensions 6 Figure 2 ICA100 Wiring 7 Figure 3 ICA200 300 Adjustable Mount 9 Figure 4 ICA200 300 Mounting Dimen...

Page 3: ...three way systems Adjustable mount ICA200 300 Series Hand held microphone option for master stations Foot switch option for master stations Specifications SERIES ICA100 ICA200 300 ICA400 500 SUPPLY VOLTAGE 12 VDC 12 VDC 12 VDC OUTPUT POWER 8 WATTS 16 WATTS 16 WATTS FUSE 3 AMP RECOMMENDED 3 AMP SLOW BLOW 25 X 1 25 MDL 3 AMP SLOW BLOW 25 X 1 25 MDL DIMENSIONS MASTER IN INCHES 5 25 x 4 x 1 5 8 25 x 5...

Page 4: ...ss background noise is picked up by the hands free remote station due to vibration mounting it on a rubber pad can help reduce noise Ensure a good ground connection Isolate the intercom ground wire from other grounds that can be noisy strobes radios priming motors etc Make interconnecting cable runs as short as possible Secure excess intercom cable in a figure 8 pattern The foot switch option requ...

Page 5: ... Install Remote Station 1 Place station box in position with mounting post through the holes and secure with two nuts The nuts should be hand tight plus 1 4 turn 2 Connect station box four wires to cable Refer to Figure 2 for wiring details Install Master Station 1 Place station box in position with mounting post through the holes and secure with two nuts The nuts should be hand tight plus 1 4 tur...

Page 6: ...ICA100 Rev171109 6 Figure 1 ICA100 Mounting Dimensions Two 3 4 holes are needed Remote Station Master Station Two 3 4 holes are needed 4 2 5 8 3 4 3 4 2 1 2 5 1 4 4 3 8 2 1 4 1 5 8 3 1 4 1 1 16 1 1 16 ...

Page 7: ...between the master station box and the 12 VDC power source Master Station 12 VDC GND Red Black Yellow White Red Black Remote Station Black White Yellow Red A one to one cable connects the two stations Black to Black White to White Red to Red Yellow to Yellow Master station may have a power on LED ...

Page 8: ...ox locations Refer to Figure 5 or 6 for wiring details 4 For three way system ICA300 install the cable with 5 pin connector between master stations A and B box locations Refer to Figure 6 for wiring details Install Remote Station 1 Place mounting bracket in position and secure with four screws 2 If bracket was removed from box place remote station box in position and install rubber bushings and mo...

Page 9: ...es Figure 4 ICA200 300 Mounting Dimensions Drill the holes for 1 4 inch mounting hardware 4 1 4 3 4 3 4 3 Figure 3 ICA200 300 Adjustable Mount Adjustable Provide enough slack in the cable s for the station box to be adjusted as needed Station Box Adjustment Knob Mounting Bracket Rubber Bushing ...

Page 10: ... To Remote Station Figure 5 ICA200 Wiring Remote Station Master Station GND 12 VDC Fuse 3 AMP 3 Pin Molex Connector Wiring White Yellow Black If the PTT option is installed on the remote station a 5 pin Molex will be used ...

Page 11: ...n To Master Station B Figure 6 ICA300 Wiring Remote Station Fuse 3 AMP Master Station B GND 12 VDC Master Station A GND 12 VDC Fuse 3 AMP 3 Pin Molex Connector Wiring White Yellow Black 5 Pin Molex Connector Wiring Red Yellow White Black ...

Page 12: ...hield 4 Install the cable with 3 pin connector between remote and master station box locations Refer to Figure 8 or 9 for wiring details 5 For three way system ICA500 install the cable with 5 pin connector between master stations A and B box locations Refer to Figure 9 for wiring details Install Remote Station 1 Place station box in position and secure with four screws 2 Connect station box 3 pin ...

Page 13: ...ng Dimensions Master Station Cutout and Mounting Holes Remote Station Cutout and Mounting Holes Suggested Panel Opening 5 1 8 H x 5 1 8 W Suggested Panel Opening 6 3 8 H x 5 1 8 W Drill the holes for number 10 mounting hardware 6 3 4 5 1 2 5 1 2 5 ...

Page 14: ... Figure 8 ICA400 Wiring To Remote Station Master Station GND 12 VDC Fuse 3 AMP Remote Station 3 Pin Molex Connector Wiring White Yellow Black If the PTT option is installed on the remote station a 5 pin Molex will be used ...

Page 15: ...Wiring To Master Station B To Remote Station Master Station B GND 12 VDC Fuse 3 AMP Remote Station GND 12 VDC Fuse 3 AMP 5 Pin Molex Connector Wiring 3 Pin Molex Connector Wiring White Yellow Black Red Yellow White Black Master Station A ...

Page 16: ...r station B and the remote station System Options Handheld Microphone Option This option is for installations in high noise areas The microphone plugs into a receptacle on the station box The system can be keyed to transmit with the microphone switch or the PTT button on the station box Remote Station with PTT Button Option This option is for installations where a remote station with hands free op...

Page 17: ...ice is heard at remote station and master station B 4 Release PTT button 5 Press and hold PTT button on master station B box 6 Speak into the box and adjust volume knob for transmit and receive level Result Voice is heard at remote station and master station A 7 Release PTT button 8 Speak into remote station box Result Voice is heard at master station A and master station B Handheld Microphone and...

Page 18: ...ICA100 Rev171109 18 NOTES ...

Page 19: ...ICA100 Rev171109 19 NOTES ...

Page 20: ...ICA100 Rev171109 20 ...