DFA400 Rev0708
22
Program Code Descriptions
When a valid three-digit program code has been entered, a program value or option
shows in the display. The
MODE
and
TOTAL
buttons are used change the data.
Press the
MODE
button to select the digit to be change. The digit flashes. Press
the
TOTAL
button to change the digit or the option choice.
Code 311 Flow Rate Increment Set Point
Factory programmed value:
400
Options:
0000 to 9999
This code sets where the digital display changes from incrementing by 1 to
incrementing by 10. The display values increment by 1 at flow rates below the set point
and by 10 at flow rates above the set point. This code does not impact flow warnings,
flow cutoff settings, or flow rate display when in the calibration program.
Code 312 ID Number
Factory programmed value:
Id 0
Options:
0 to 99
This code sets the datalink identification (ID) number for the display module. The
display is programmed with an ID number between 0 and 99. When a display module
is programmed with Id 0 no data is output to the datalink. The ID number assigned to
a remote display must match the ID number of the primary display. The ID number
for a summing or accumulator display is not used.
Code 313 Module Function
Factory programmed value:
Pri
Options:
Pri, SLA
This code sets the datalink function of the display module. Two program choices
are available. Pri (primary) sets the module as a primary display. The display module
must be programmed as primary to interpet flow sensor information. SLA (slaved) sets
the module as a remote display.
Code 315 High Flow Warning
Factory programmed value:
0 (High flow warning is disabled.)
Options:
0001 to 9999
This code sets the high flow warning. When the flow rate is above the high
flow warning programmed value, the flow display alternately flashes the flow rate
and -HI-.