Page | 17
Problem
Cause/Solution
Propane alarm is triggered or
there is a smell of sulfur or
rotten eggs inside the RV.
Immediately close the main valve on the propane tank. There may be a leak
in the system. Open doors and windows so that any propane can escape to
the outside. Avoid open fire under any circumstances until the smell has
dissipated, and do not operate any electrical switches. The system must be
inspected by a technician. If there is no problem with the propane system,
the smell may indicate a coach battery overload or short circuit. If this is the
case, you should be able to see a white powder (sulphuric acid) on or around
the battery. Please do NOT touch it, because the acid is corrosive! Please
call our OnRoad-Service so that we can arrange for an appointment with a
technician.
WATER SYSTEM
FRESHWATER TANK (POTABLE WATER/TANK FILL)
Your motorhome is equipped with an integrated 189-litres/50-gallon fresh
water tank. It is not automatically refilled by hooking up to the city water
connection. It must be refilled separately through the Potable Water/Tank
Fill inlet at the passenger side.
CAUTION:
Never empty the freshwater tank entirely because this may damage the water pump. You as the
renter are liable for such damages. We take no responsibility for any expenses and/or time loss
due to damages resulting from an insufficient amount of water in the water tank.
Troubleshooting: Freshwater Tank
Problem
Cause/Solution
Freshwater tank remains
empty despite refilling.
Be sure not to confuse the freshwater tank inlet (passenger side) with the city
water connection or the sewer flush/sani flush (both at the driver side). The
freshwater tank does not automatically refill through the city water connection
but must be refilled separately.
WATER PUMP
If you use the integrated water tank for freshwater supply, you need to turn on the water pump. The water pump
is controlled via the integrated touch pad which is located on the wall left of the bathroom door.
Please turn off the pump
-
while you are driving,
-
if you do not use it for an extended time,
-
when you are using the city water connection
because it may overheat and you as the renter are liable for any
resulting damages.
Troubleshooting
: Water Pump
Problem
Cause/Solution
Water pump does not
start.
1.
The 12 Volt plug-in fuse has burnt. Please check the 12V plug-in fuses and
replace where necessary.
2.
The battery voltage is too low. Please check the coach battery level on the
battery and tank indicator panel, and if necessary, recharge the battery.
3.
The pump is faulty. Please call our OnRoad-Service.