background image

Kit No. 226545903

SubDrive50 Connect

Fan Replacement Install Guide

Summary of Contents for SubDrive50 Connect N3R

Page 1: ...Kit No 226545903 SubDrive50Connect Fan Replacement Install Guide ...

Page 2: ...ietly This test should not be run for more than 5 seconds 2 Test that the fan power supply works properly Cycle power to the drive Verify that the fan runs for 3 5 seconds during the power up initialization The bracket kit comes preassembled SUBDRIVE50 CONNECT FAN REPLACEMENT INSTALL GUIDE s WARNING Serious or fatal electrical shock may result from contact with the internal electrical components D...

Page 3: ...ubDrive50 Fan Replacement Kit provides repairability to drives in which the existing fan has been damaged failed or is otherwise inoperable TOOLS AND HARDWARE REQUIRED The installation of the SubDrive50 Fan Replacement requires a screwdriver INSTALLATION PROCEDURE STEP 1 Verify the fan replacement kit STEP 2 Remove the four screws from the bottom of the enclosure ...

Page 4: ...the main board STEP 4 Remove the fan from the enclosure STEP 5 Locate the airflow indication arrow on the side of the fan Position the fan so that the air is directed into the enclosure SubDrive50 SUBDRIVE50 CONNECT FAN REPLACEMENT INSTALL GUIDE ...

Page 5: ...he replacement fan into the enclosure STEP 7 While holding the fan in place with one hand secure it to the enclosure using the four screws Torque the screws to 9 in lbs SUBDRIVE50 CONNECT FAN REPLACEMENT INSTALL GUIDE ...

Page 6: ...y that fan turns on and is working properly If you experience any difficulty in performing these steps consult your local Franklin Electric representative or call the Franklin Electric Technical Service Hotline at 1 800 348 2420 SUBDRIVE50 CONNECT FAN REPLACEMENT INSTALL GUIDE ...

Page 7: ......

Page 8: ...9255 Coverdale Rd Fort Wayne Indiana 46809 Tel 260 824 2900 Fax 260 824 2909 franklinwater com TOLL FREE HELP FROM A FRIEND Franklin Electric Technical Service Hotline 800 348 2420 226546103 Rev 0 06 16 ...