![Franklin Electric MonoDrive Owner'S Manual Download Page 36](http://html.mh-extra.com/html/franklin-electric/monodrive/monodrive_owners-manual_2328786036.webp)
COMMUNICATIONS
FE Connect Mobile Application
36
Drive Configuration Using the FE Connect App
The
Setup
page of the FE Connect App is divided into sub-categories:
1.
Pump and Motor Settings
2. Pressure Control
3. Underload
4. Duplex Alternator
5. Advanced Options
6. Available Firmware
IMPORTANT:
If using the app to control basic settings, DIP SW1 Position 1 (FE Connect switch)
must be—and remain—in the ON (up) position. Otherwise, the drive will default to the settings
made through the DIP switches and rotary knobs on the drive itself.
Pump and Motor Settings
Enter the required settings based on the pump and motor nameplate information. Refer to
for detailed information.
The FE Connect App adds additional settings for more precise motor control:
Motor Poles:
Select either a 2- or 4-Pole motor (surface applications).
Motor Overload Current:
Set the exact current rating of the motor, which will override the DIP
switch presets (surface applications).
Minimum and Maximum Output Frequency:
Set an exact frequency range for more precise con-
trol than the DIP switch presets.
Pressure Control
Sensor Type:
This parameter sets which type of pressure sensor is being used.
•
Switch – Use this setting when connecting to a standard pressure sensor.
•
Transducer (PSI) – Use this setting for a 4-20mA pressure transducer scaled to psi.
•
Transducer (bar) – Use this setting for a 4-20mA pressure transducer scaled to bar.
Summary of Contents for MonoDrive
Page 1: ......
Page 56: ...SPECIFICATIONS Notes 56 Notes ...
Page 57: ...SPECIFICATIONS Notes 57 Notes ...
Page 58: ...SPECIFICATIONS Notes 58 Notes ...
Page 61: ...SubDrive15 20 30 50 MonoDrive MonoDriveXT Connect NEMA 3R Manuel d utilisation ...
Page 120: ...SPÉCIFICATIONS Normes en vigueur 60 Remarques ...
Page 123: ...SubDrive15 20 30 50 MonoDrive MonoDriveXT Connect NEMA 3R Manual del propietario ...