This  instruction  sheet  provides  you  with  the  information  required  to 
safely  own  and  operate  your  product.  Retain  these  instructions  for 
future reference.
The product you have purchased is of the highest quality workmanship 
and material, and has been engineered to give you long and reliable 
service.  This  product  has  been  carefully  tested,  inspected,  and 
packaged to ensure safe delivery and operation. Please examine your 
item(s) carefully to ensure that no damage occurred during shipment. 
If damage has occurred, please contact the place of purchase. They 
will assist you in replacement or repair, if required.

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING 

TO  INSTALL,  OPERATE,  OR  SERVICE  YOUR  PRODUCT.  KNOW 

THE PRODUCT’S APPLICATION, LIMITATIONS, AND POTENTIAL 

HAZARDS. PROTECT YOURSELF AND OTHERS BY OBSERVING 

ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH THESE 

INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR 

PROPERTY DAMAGE!

DESCRIPTION 

This is a submersible effluent pump for use in basins or lift stations, 
and is suitable for pumping sewage, effluent, wastewater, and other 
non-explosive, non-corrosive liquids with up to 1/2" spherical solids.

SAFETY GUIDELINES

  1.  Make  certain  pump  is  disconnected  from  power  source  before 

attempting to service or remove any component.

  2.  Do  not  use  to  pump  flammable  or  explosive  fluids  such  as 

gasoline,  fuel  oil,  kerosene,  etc. 

DO  NOT

  use  in  explosive 

atmospheres or hazardous locations as classified by NEC, ANSI/
NFPAT. Pump should be used with liquids compatible with pump 
component materials.

  3.  Do not handle the pump with wet hands or when standing on a 

wet or damp surface or in water.

  4.  Do not pull the pump out of the water by the power cord when the 

pump is operating or connected to power source.

  5.  This  pump  is  supplied  with  a  grounding  conductor  and/or 

grounding  type  attachment  plug.  To  reduce  the  risk  of  electrical 
shock,  be  certain  that  it  is  connected  to  a  properly  grounded 
grounding type receptacle.

  6.  The  National  Electric  Code  requires  a  ground  fault  circuit 

interrupter  (GFCI)  be  installed  in  the  branch  circuit  supplying 
fountain equipment, pools, etc.

  7.  In any installation where property damage and/or personal injury 

might  result  from  an  inoperative  or  leaking  pump  due  to  power 
outages, discharge line blockage, or any other reason, a backup 
system(s) and/or alarm should be used.

  8.  Support  pump  and  piping  when  assembling  and  when  installed. 

Failure to do so may cause piping to break, pump to fail, motor 
bearing failures, etc.

  9.  This pump’s motor housing is filled with a dielectric oil for motor 

heat  transfer  and  lifetime  lubrication  of  the  bearings.  This  oil  is 
non-toxic to aquatic life. However, suffocation can occur if oil is 
left on the water surface. If oil escapes the motor housing it can 
be removed from the surface quickly by placing newspapers on 
the water surface to soak up the oil.

 10. The pump motor is equipped with an automatic resetting thermal 

protector and may restart unexpectedly. Protector tripping is an 
indication  of  motor  overloading  as  a  result  of  excessively  high  or 
low voltage, inadequate wiring, incorrect motor connections, or a 
defective motor or pump.

ELECTRICAL CONNECTIONS

  1.  Check  the  pump  label  for  proper  voltage  required.  Do  not 

connect to voltage other than that shown.

  2.  If pump is supplied with a 3-prong electrical plug, the third prong 

is to ground the pump to prevent possible electrical shock hazard. 

DO  NOT  REMOVE

  the  third  prong  from  the  plug.  A  separate 

branch circuit is recommended. 

    Do not use an extension cord. Do not cut plug from the cord. If 

the plug is cut or the cord is shortened, then this action will void 
the warranty.

  3.  If the cord is equipped with stripped lead wires, such as on 230V 

models,  be  sure  that  the  lead  wires  are  connected  to  a  power 
source  correctly.  The  green/yellow  wire  is  the  ground.  The  blue 
(or white) and brown (or black) are live.

  4.  Check local electrical and building codes before installation. The 

installation must be in accordance with their regulations as well as 
the most recent National Electrical Code (NEC).

  5.  To  conform  to  the  National  Electrical  Code  all  pumps  must  be 

wired with 14 AWG or larger wire. For runs to 250', 14 AWG wire 
is  sufficient.  For  longer  runs,  consult  a  qualified  electrician  or  the 
factory.

  6.  Pump  should  be  connected  or  wired  to  its  own  circuit  with  no 

1

6EN-CIA-SFS

6EN-CIA-RF

6EN-CIM

FIG. 1 - TYPICAL INSTALLATION • INSTALLATION TYPE • 

INSTALACION TIPICA   (6EN-CIA-SFS SHOWN)

Franklin Electric Co., Inc.

Oklahoma City, OK

1-800.701.7894 • Fax: 1-405.228.1561

 www.LittleGiantPump.com

  [email protected]