OPERATION TESTING
Electrical Connections
6
Electrical Connections
Check the pump label for proper voltage required. Do not connect to voltage other than that shown. Use a
ground fault circuit interrupter (GFCI) if required by code. The pump should be connected or wired to its
own circuit, with no other outlets or equipment in the circuit line. The fuses and circuit breaker should be of
ample capacity in the electrical circuit.
The 9EC-CIA-RF, 9ECH-CIA-RF and 10ECH-CIA-RF pumps have automatic
switches with piggyback plugs on the switch cords. For automatic opera
-
tion, plug the pump cord into the float switch cord. Plug the float switch
cord (with pump cord attached) into the GFCI outlet.
OPERATION TESTING
If the pump does not operate properly, consult
. If the solution still cannot be
found, please contact the place of purchase or an authorized service center.
Do not let the unit run dry (without liquid). It is designed to be cooled by pumping fluid. The seal may be
damaged and the motor may fail if the pump is allowed to run dry. Pump should be totally submerged for
proper cooling of the motor when pump is operated for extended periods.
Pump
HP
Voltage (VAC)
Breaker Amps
9EC
4/10
115
15
9ECH
4/10
115
15
10ECH
1/2
115
15
Risk of severe injury or death by electrical shock.
•
Always disconnect the electrical power before touching the pump or discharge.
•
Check local electrical and building codes before installation. The installation must be in accordance
with their regulations as well as the most recent National Electrical Code (NEC).
•
The flexible jacketed cord assembly mounted to the pump must not be modified in any way, with the
exception of shortening the cord to fit into a control panel. Any splice between the pump and the
control panel must be made within a junction box mounted outside of the basin and comply with the
National Electrical Code. Employ a licensed electrician.
•
Do not use the power cord for lifting the pump.
•
Do not remove the third prong from the plug, or cut plug from cord. These actions will void the warranty.
Risk of damage to pump or other equipment.
•
Do not attempt to run the pump without water; this could result in permanent damage to the pump.
•
If pump is run dry, it may damage pump and will void the warranty.