WATER COOLER InsTRuCTIOns
MOdELs: KEP8FA, KEP14FA, KEPLF16FAW, KEPLF16FAWCP, KEPLF20FA, KEPLF20FACP,
KEnsFd8, KEnsFd14, KEnsFd16W, KEnsFd16WCP, KEnsFd20, KEnsFd20CP
1. InsPECTIOn
Inspect the carton and water cooler for evidence of rough handling and concealed damage. Damage claims should be filed with the carrier.
2. MAInTEnAnCE
The only maintenance operation required is the removal of dirt and lint from the condenser. Inspection should be made at 3 month intervals.
Disconnect the power supply cord, then clean the condenser with a small stiff non-wire brush when required. Observance of this procedure will
insure adequate air circulation through the condenser so operation is efficient and economical.
3. OVERLOAd PROTECTIOn
The compressor motor is equipped with an automatic reset protector which will disconnect the motor from the line in case of an overload.
4. LuBRICATIOn
This unit is equipped with a hermetically sealed compressor and requires no additional lubrication. The fan motor on this unit seldom needs
oiling, but if required, a few drops of SAE 10 oil should be used.
5. TO PuT WATER COOLER InTO sERVICE
a)
Note:
The following states require a licensed plumber to install cooler; AR, GA, MA, MI, OK, RI, SC, SD, TX, VT and WI. CA, KS, MN, NM and
OR allow for a state-registered installer or contractor as well. State and local plumbing codes may prohibit the use of saddle tapping valves
for water line connection in some applications. All connections must conform to applicable plumbing codes.
b) The back of the water cooler may be installed as close to the wall as the plumbing will allow. Maintain a minimum clearance of 4" [102mm]
from any louvered panel to assure adequate air flow.
c) Install a trap in the waste line and a shut-off valve in the water supply line. Internal waste line and trap should be wrapped with insulating tape
to prevent sweating. Use clean 3/8" OD copper tubing water supply line.
d) To fill the cold water tank, open the shut-off and bubbler valves.
e) On hot and cold tank, fill the water heating tank by drawing water form the hot water dispenser until the stream is free of bubbles.
f) Check the available power supply against the water cooler data plate to assure correct electrical service. Plug service power cord into
receptacle.
Note:
For water coolers with IEC power inlet, connect female portion of service cord into power inlet and secure cord to
plastic strain relief.
g) If a hot and cold model, make certain the hot water tank contains water, then turn the hot water tank heater switch to the
ON position.
DANGeR:
WATER DISPENSED FROM HOT FAUCET CAN SCALD.
6. WATER VALVE AdJusTMEnT On WATER COOLEd MOdELs
The valve is factory set and will not ordinarily require readjustment. If adjustment is required, turn the adjusting stem of the valve counterclockwise to
increase flow, clockwise to decrease flow. Do not adjust more than 1/8 turn at a time and never adjust more than 1/2 turn total in either direction.
7. TO dIsCOnTInuE usE OF WATER COOLER
a) Disconnect the power supply cord.
b) Close the water shut-off valve.
c) On hot and cold model, set the hot water heater switch to the OFF position.
d) Provide container to catch water and remove drain plug(s) from tank(s).
e) Remove or open bubbler valve and, if any, the glassfiller or hot valve.
f) ALWAYS DRAIN ALL WATER WHEN FREEZING TEMPERATURES ARE ANTICIPATED AND BEFORE SHIPPING THE WATER COOLER.