Warranty, Support & End of Life Disposal
Fault finding & General cleaning
Wall Mounted Tap Sensor
Installation & Operating Instructions
Dart Valley Systems
|
Kemmings Close
|
Long Road
|
Paignton
|
Devon
|
TQ4 7TW | UK
T +44 (0)1803 529 021
|
F +44(0)1803 559 016
|
www.dartvalley.co.uk
|
1. SENSOR WILL NOT OPERATE AT ALL
- Check all electrical connections (see Fig 3 on page 3).
- Check fuse (Mains/PSU model only) max 3 amp fuse
- Voltage too low. Check tap input voltage (PSU output voltage
- 6v DC).
- Voltage too low. Replace battery DVS code AT00-026 (CRP2
or DL223A) Lithium Cell only.
- Check / Clean all connectors (shown in Fig 3).
- Check for cable damage.
- For mains/PSU and battery models, disconnect for 1 minute
then reconnect and allow sensor to recalibrate.
- Check water is turned on.
- Check the solenoid valve is fitted correctly.
- Check valve operation.
- Check for dirt or debris in the solenoid valve.
- Water pressure is too low / too high.
2. SENSOR OPERATES IN REVERSE
(Water runs when hand is moved away from sensing area and
stops when returned to sensing area)
- Reversed valve polarity (contact Dart Valley Systems)
3. SENSOR OPERATES INTERMITTENTLY
- Clean sensor lens (with nonabrasive materials only).
- Shower may be installed too close to an R.F. interference
source or direct sunlight.
- Water pressure too low for valve to operate reliably (minimum
1.0 BAR required) for standard solenoid valves.
- Voltage too low. Check tap input voltage (PSU output voltage
- 6v DC).
- Voltage too low. Replace battery, CRP2 or DL223A Lithium
Cell only.
- Disconnect power for 1 minute, then reconnect and allow the
sensor to recalibrate.
General Cleaning
Valve Servicing
The valve will require periodical servicing and cleaning, please
contact DVS for servicing.
Do not attempt to dismantle the valve if you are unfamiliar with
electronic solenoid valves.
Optional Parts
AC03-019
Standard Y-strainer - 15mm compression
AC17-004
Low pressure 0-1.0 Bar 6V 4mm solenoid valve
AT00-200
1m PSU cable extension
AT00-201
2m PSU cable extension
Warranty
The tap sensor kit is guaranteed for 5 years from purchase
against defective material and assembly.
The solenoid valve is guaranteed for 12 months, subject to water
condition, however it is expected that the valve internals will
operate efficiently for many years.
Support
For technical support please visit our technical pages on our
website at www.dartvalley.co.uk or contact us by e-mail at
[email protected] Alternatively, you can telephone us
direct on 01803 529021 and our customer service team will be
pleased to help you.
Disposal of electrical and electronic equipment
The use of this crossed out wheeled bin logo indicates
that this product needs to be disposed of separately to
any other household waste.
Within each of the European Union member countries, provisions
have been made for the collection and recycling of unwanted
electrical and electronic equipment. Outside of the EU it will be
necessary to dispose of this product at your local community
waste collection or recycling centre. In order to help preserve our
environment we ask that you dispose of this product correctly.
Please contact your local council for collection centre details.
Disposal of waste batteries
The use of this crossed out wheeled bin logo indicates
that the battery needs to be disposed of separately to
any other household waste.
Within each of the European Union member countries, provisions
have been made for the collection and recycling of waste
batteries. Outside of the EU it will be necessary to dispose of this
at your local community waste collection or recycling centre.
In order to help preserve our environment we ask that you
dispose of this battery correctly. Please contact your local
council for collection centre details.
Head Office
Dart Valley Systems Ltd
Kemmings Close
Long Road
Paignton
Devon
UK
TQ4 7TW
Contact Details
t : +44 (0) 1803 529021
f : +44 (0) 1803 559016
e : [email protected]
w : www.dartvalley.co.uk
Step 1 :
Safety first
Step 2 :
Parts
These instructions relate to the use of the
Wall Mounted Tap
Sensor
only, any external or ‘add-on’ parts will be supplied with
separate instructions.
Appropriate personal protective equipment must be worn when
installing, calibrating and commissioning this product.
It is recommended that the electrical part of the installation be
carried out by a qualified electrician in accordance with the latest
electrical regulations. It is also recommended that any plumbing
is carried out by a qualified plumber.
This is a sophisticated electronic device which must be installed
correctly to perform correctly.
If the appliance is used by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, they must be given adequate
supervision or instruction concerning use of the appliance by a
person responsible for their safety. Children should be supervised
to ensure that they do not play with the appliance.
Your kit will comprise the following parts*:
IMPORTANT:
Please read these instructions carefully
and follow each stage in order!
*Not to scale
Instruction Manual (x1)
Solenoid Valve
AC17-006
Battery Box
AT00-024
DVS Power Supply
AT00-029
Y Splitter Lead
AT00-202
Optional Y Distributor
AT00-212
or
Sensor
AC02-017
Page 4
PP
00
-424
2
70
31
8
PP
00
-424
2
70
31
8
AC02-017
IMPORTANT:
Do not use abrasive materials or cleaners. Only
use soap and water or nonabrasive cleaners.