18. Replacing the Solenoid Valve Cartridge
18.1
Close the corner valves.
18.2
Trigger the valve.
18.3
Loosen the screw (a) with an Allan key.
18.4
Pull the housing (b) from the base (c).
18.5
Remove the screws (d).
18.6
Remove the mounting bracket (e).
18.7
Remove and replace the solenoid valve cartridge (f).
18.8
Reassemble in the reverse order.
19. Fault Correction
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform our customer service department!
Fault
Cause
Remedy
Water does not flow
– Voltage supply interrupted
➯
Restore it
– Water-flow volume regulator closed
➯
Open it
– Grit filters are clogged with dirt
➯
Clean them
– Cleaning clip in front of the fitting
➯
Remove
– Solenoid valve faulty
➯
Replace it
Water flows
continuously
– Solenoid valve faulty
➯
Replace it
Water flow too weak
– Corner valves not fully opened
➯
Open it
– Grit filters are clogged with dirt
➯
Clean them
– Aerator calcified
➯
Replace it
– Solenoid valve faulty
➯
Replace it
– Supply pressure too low
➯
Check it
Water is too hot
– Cold water is turned off
➯
Open it
– Filter in cold-water part is dirty
➯
Replace it
– Non-return valve faulty
➯
Replace it
Water is too cold
– Hot water is turned off
➯
Open it
– Filter in hot-water part is dirty
➯
Replace it
– Non-return valve faulty
➯
Replace it