24. Fault Correction
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform our customer service department!
Fault
Cause
Remedy
Water does not flow
– Water supply interrupted
➯
Restore it
– Water-flow volume regulator closed
➯
Open it
– Voltage supply interrupted
➯
Restore it
– Grit filter is clogged
➯
Replace it
– Solenoid valve faulty
➯
Replace it
– Sensor faulty
➯
Replace it
Water flows conti-
nuously
– Solenoid valve faulty
➯
Replace it
Flow duration too
short or too long
– Flow duration setting incorrect
➯
Adjust it
Water flow too weak
– Water volume regulator is not fully
opened
➯
Open it
– Shower head calcified
➯
Clean it
– Grit filter is clogged
➯
Clean it
– Supply pressure too low
➯
Check it