![Franke 2000100375 Installation And Operating Instructions Manual Download Page 7](http://html1.mh-extra.com/html/franke/2000100375/2000100375_installation-and-operating-instructions-manual_2327820007.webp)
7
ZMI
_001_
2000
1003
75-ZAQ
U
A00
7_#S
EN_#A
QU_#V
2.f
m
10. Electrical Connection
Output characteristic
Connecting the output lines
☞
Apply wire-end ferrules to flexible lines
10.1
Connect the cores of the output line according to the pin configuration on the T-
junction or on the fitting.
SELV power supply - pin configuration
10.2
Connect the output line to the compact system power supply.
10.3
Insert the power plug into the socket.
11. Fault correction
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform our service department!
Pin P1
Signal
Level
Curren
t
Colour C1
1
Not used
yellow
2
Not used
green
3
GND
0 V
white
4
Not used
brown
5
24 V
24 V +
0.5 A
red
Fault
Cause
Remedy
No output voltage
present
– Voltage supply interrupted
➯
Restore
– Compact system power supply
defective
➯
Replace
– Output load too high (possibly short
circuit)
➯
Eliminate the
source of the fault
on the connected
components