2 - INSTALLATION 

 

2.1 Before installing 

In order to start the AP aerotherm, the following conditions are required: 
•  connection  to  the  electric  power  supply  with  voltage  and  frequency  suitable  for 
the machine and with grounding and safety devices; 
• connection to hot/cold water supply; 
•water drain connection. 
 

The installation must meet the safety requirements 
provided by local regulation in force.

 

 

 

 
Make sure that all the connections necessary to operate the equipment have been properly prepared. 
 

2.2 Positioning 

The AP aerotherm must be installed horizontally, hanging off the ground, with the condense drain 
hole siding down. 
Use the threaded inserts for hanging the machine holding it in the correct operating position with 
an  appropriate  fixing  system  avoiding  vibration  (the  distance  between  holes  is  shown  in  Figure 
2.1; use vibrations reducer devices);  
 

 

 

AP15 - AP25 

AP30 - AP35 - AP40 - AP50 - AP60 - AP70 – AP80 – 

AP100 

Threaded inserts quotes for suspension / brackets Fig. 2.1 

 
The  positioning  of  the  AP  must  be  done  by  maintaining  the  minimum  recommended  distance  that  allows  the 
correct operation of the machine and to perform maintenance when needed. 
Choose, depending on the type on installation adopted, the most suitable position for the humidification and the 
cooling of the environment. 
 
 

The instalment of the machine must meet the safety distance and protections in  
accordance with the norm DIN EN 294 – 4, 4.1, 4.2.  

 

 

Summary of Contents for 2408000

Page 1: ...OT AND COLD WATER AEROTHERMS TRANSLATED VERSION FROM ITALIAN TO E N G L I S H Before installing or running the unit it is obligatory to carefully read and consult this manual Manual Version 05 000 201...

Page 2: ...arts 10 1 11 Transport and handling 11 1 12 Warranty 11 1 13 Manufacturer s identification data 11 1 14 Statements 11 1 15 Declaration of conformity 12 2 INSTALLATION 13 2 1 Before installing 13 2 2 P...

Page 3: ...ace water or any other liquids into the device In the scenario of the device becoming wet immediately turn off the electricity by lowering the switch on the electrical panel of your system and disconn...

Page 4: ...l must be stored in a secure environment protected from moisture and heat and near the referring device The manufacturer if requested by the User may provide additional copies of the instruction manua...

Page 5: ...perating procedures defined by the manufacturer of the machine 1 6 Glossary and pictographs In this section we list the non common terms included in the manual The following also explains the abbrevia...

Page 6: ...ected result or endanger the safety of the personnel involved STATE OF THE MACHINE The state of the machine includes the operating mode for example running in automatic mode maintained action control...

Page 7: ...le to operate the machine under normal conditions to run it with the maintained action control JOG with disabled protections and enabled to any kind of operation of electrical adjustment maintenance a...

Page 8: ...impose PROHIBITION OBLIGATION Pictograph Denomination Hazardous voltage Entanglement Dragging General danger Do not remove safety devices Prohibition of cleaning oiling greasing repairing or adjustin...

Page 9: ...are made in PA PC and ABS the screws are stainless steel made Fasteners are in stainless steel This device must be used only for the functions for which it was intended and designed Heating Cooling wo...

Page 10: ...tenance AP 10 1 10 Description of the parts Fig 1 3 Exchanger cover Water inlet Aerotherm body Protection grill Fan Water outlet Air louvers optional Exchanger N 4 threaded insert M8 to suspend Conden...

Page 11: ...eed for 12 months from the date of manufacture for all failures attributed to a proven manufacturing or material defect All the parts damaged by transport improper maintenance negligence inability to...

Page 12: ...2408060 2408061 2408070 2408071 2408080 2408081 2408090 2408091 2010 Series Registration number Year of construction AP Aerotherm Commercial denomination Heating or cooling of rooms Intended use Meet...

Page 13: ...nd with the condense drain hole siding down Use the threaded inserts for hanging the machine holding it in the correct operating position with an appropriate fixing system avoiding vibration the dista...

Page 14: ...ection to the piping lines of water supply inlet and outlet and drainage at the proper points Fig 1 3 All the hydraulic connections must meet the local regulation in force 3 OPERATION 3 1 Getting star...

Page 15: ...remove the 4 screws holding the safety grill of the fan to the body of the appliance Remove the fan and replace it with a new one Tighten the screws you removed previously and check that the fan blad...

Page 16: ...FRANCO srl Manual of use and maintenance AP 16 Fig 4 1 Fig 4 2 Fig 4 3 Fig 4 4 Fig 4 5...

Page 17: ...97 580 64 108 AP40 26 2 5 1 865 720 430 497 580 64 108 AP50 32 5 1 1 865 720 430 497 580 64 128 AP60 32 5 1 1 865 720 430 497 580 64 128 AP70 32 5 1 1 865 720 430 497 580 64 128 AP80 39 6 42 M1 865 72...

Page 18: ...5 5 C C T TA AI I 8 85 5 C C 7 70 0 C C 7 70 0 C C 5 55 5 C C 6 60 0 C C 4 45 5 C C 5 50 0 C C 3 35 5 C C 1 15 5 C C 1 54 1 28 1 10 0 91 1 10 0 C C 1 45 1 18 1 01 0 82 5 5 C C 1 36 1 09 0 90 0 74 0 0...

Page 19: ...4 87 23 67 837 5 1 27 2 3 500 A AP P3 35 5 6 03 6 03 24 25 1 037 7 4 52 3 5 000 A AP P4 40 0 7 02 7 02 24 64 1 207 9 6 85 4 6 500 A AP P5 50 0 7 94 7 94 20 95 1 365 3 5 54 2 3 500 A AP P6 60 0 10 17 1...

Page 20: ...only original spare parts Orders must be made by specifying what follows Device model Reference of the piece as indicated as follows Quantity of items to be ordered Address of the client 1 10 8 4 5 3...

Page 21: ...AP 100 Pos Art Description 1 2 2 2 3 4 5 6 7 8 8 8 9 10 11 11 12 12 2404002 2401002 2401003 2401004 2404051 2404061 2404063 2400002 2404052 2406001 2406002 2406003 2404054 7303004 2402002 2402003 8101...

Page 22: ...tely tightened Make sure that the electricity supply characteristics are exactly as shown in the table par 5 1 Install a differential magnetic switch upstream of the device Protect with a suitable mot...

Page 23: ...r flow or the air flow is feeble The motor is broken Contact qualified and authorized personnel to replace the motor The outlet air isn t heated or cooled The thermal circuit is not working Check the...

Page 24: ...RANCO S r l Headquarters and plant Via Nazionale n 80 12010 CERVASCA CUNEO Italy Tel 39 0171 611663 Fax 39 0171 612337 www francosrl com info francosrl com For further information requests or suggesti...

Reviews: