5 - Electrical Installation
For safety purposes, only competent personnel should perform the electrical installation. All
equipment should be installed to current Electrical Regulations and Standards.
In order to obtain the maximum light output from the searchlight, it is essential that the full
operating voltage of the lamp fitted be applied to the lampholder contacts.
Method of Electrical Connection
1)
Disconnect the supply before working on the electrical system;
2)
The searchlight must be connected to a fused electrical supply, using suitably sized cable;
3)
If the searchlight is located a considerable distance from the supply, provision must be
made in the cable size in order to overcome the voltage drop.
The following table below indicates the maximum length of cable to be used for the supply
cable to the power supply unit:
Searchlight
115v 300w
240v 300w
Cable Size (mm²)
Distance Max
Distance Max
1.5
57 MTRS
247 MTRS
2.5
93 MTRS
404 MTRS
4.0
147 MTRS
640 MTRS
6.0
229 MTRS
997 MTRS
10.0
384 MTRS
1869 MTRS
4)
Whenever possible cable terminations should be made below deck and with approved
terminal devices;
5)
If a spare auxiliary fuse or circuit breaker is not available, one of the correct type and rating
should be fitted and connected to a positive supply. It is advisable to locate a bus bar or
main connection and avoid any direct connection to the supply:
6)
The following colour coding system should be used for the customer supply cable:
Brown
- Live
Blue
- Negative
Green/Yellow - Earth
Note: This equipment must be earthed.