FRAMOS Industrial Depth Camera D400e Series - User Manual
Version 1.0.0 from 2020-06-30
16 of 41
3.9.2
Power M8 connector, A-Coded, Male
Figure 2 – M8 PIN Layout
M8 Pin
Description
1
DC Power supply, 12-24V DC (+/- 10%)
2
Opto isolated IN
3
Opto isolated OUT
4
GND for opto isolated I/O
5
Direct coupled I/O 1 (optional)
6
Direct coupled I/O 2 (optional)
7
Not used
8
Power GND
Table 14 – M8 PIN Layout
3.10
Power Consumption
Condition
Typical
Max
Power via M8
5.5W
7W
Power via M12 (PoE)
6.9W
8W