background image

5.

Unscrew the 4x30 screws (8 pcs) and remove the wall cover panels (4 pcs).

6.

Unscrew the 4x30 screws (32 pcs) and remove the top and bottom cover panels (4

pcs).

Framery O VCR Troubleshooting instructions
[email protected]

15

Summary of Contents for O

Page 1: ...Framery O VCR Troubleshooting instructions English Version 2 0 ...

Page 2: ......

Page 3: ...power to the fans and light 41 5 2 The ceiling light does not switch on 47 5 3 The display light does not switch on 52 5 4 The control panel does not work 55 5 5 When you adjust the ceiling light the display light is also adjusted 58 5 6 One or both fans do not work 60 5 7 The fans are noisy 66 5 8 The air inside the pod does not feel fresh 72 6 Door handle and lock 82 6 1 The door handle is loose...

Page 4: ......

Page 5: ...the manufacturer s explicit prior permission Safety considerations Warning Always disconnect the pod from the power outlet before performing any maintenance To disconnect remove plug from outlet Note Read these instructions before installation or maintenance Note Use safety boots and cut resistant gloves during installation and maintenance Note The use of the pod is only permitted after it has bee...

Page 6: ...allation environment The pod is intended to be used in the following conditions Ambient temperature 15 C 30 C 59 F 86 F Humidity max 50 6 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 7: ... person inside the pod is saying and the person inside the pod can hear noises from outside the pod Cause The door is too low The door is not vertically in the middle of the door opening Solution Adjust the door height 1 Remove the caps from the hinges Framery O VCR Troubleshooting instructions info frameryacoustics com 7 ...

Page 8: ...or insert the hex key into the top of the upper hinge and turn clockwise To lower the door turn counter clockwise Note After the initial installation the door normally does not have to be lowered but raised 8 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 9: ...se and counter clockwise to lower the setting 6 Make sure that the door is aligned correctly 7 Test with a flashlight from the inside of the pod If the flashlight shines through the door seams adjust the door 8 Repeat steps 4 6 if needed 9 Close the door Framery O VCR Troubleshooting instructions info frameryacoustics com 9 ...

Page 10: ...re that both hinges have the same height setting 11 Install the caps Cause The floor of the pod is not leveled Solution Level the floor 1 Pull the carpet out from under the wall felts and remove the carpet from the pod 10 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 11: ...easure the floor module with a spirit level at four measuring points Along the sides At the edge of the floor module on the ABS strips Framery O VCR Troubleshooting instructions info frameryacoustics com 11 ...

Page 12: ...atedly and adjust the feet of the leveling screws gradually 5 Reinstall the carpet Note Make sure that the carpet is firmly in place and that there are no bumps 12 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 13: ...aighten the pod 1 Check the straightness of the pod with a spirit level on both sides If the pod is not standing straight complete the following steps 2 Remove the wall body covers Framery O VCR Troubleshooting instructions info frameryacoustics com 13 ...

Page 14: ...3 Remove the roof and bottom body covers 4 Pull the carpet out from under the wall felts and remove the carpet from the pod 14 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 15: ...he 4x30 screws 8 pcs and remove the wall cover panels 4 pcs 6 Unscrew the 4x30 screws 32 pcs and remove the top and bottom cover panels 4 pcs Framery O VCR Troubleshooting instructions info frameryacoustics com 15 ...

Page 16: ...rew the 4x30 screws 4 pcs and remove the floor cover panels 2 pcs 8 Unscrew the 4x30 screws 4 pcs and remove the roof cover panels 2 pcs 16 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 17: ...9 Remove the seal from the glass wall 10 Open the door completely 180 Framery O VCR Troubleshooting instructions info frameryacoustics com 17 ...

Page 18: ...body bolts slightly 12 Measure and push the pod walls as needed and keeping them straight tighten the bolts at the same time Note Do not overtighten the bolts 18 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 19: ...glass wall 14 Reinstall the removed parts Cause The door is sagging Solution Install an adjustment plate under the lower hinges 1 Open the door completely 180 Framery O VCR Troubleshooting instructions info frameryacoustics com 19 ...

Page 20: ...2 Lift the door to detach it 3 Unscrew the 5x30 screws 4 pcs and remove the lower hinges 20 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 21: ...into place Cause The door seal has come loose or is compressed Solution Reinstall the door seal Insert the seal into the groove Make sure that the seal is correctly installed Tip A spline roller can be a useful tool to help you work faster Framery O VCR Troubleshooting instructions info frameryacoustics com 21 ...

Page 22: ...22 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 23: ...ver will not go into the installation groove There is a gap between the roof or bottom body cover and the frame There is a big gap between two body covers Figure 1 Gap between two body covers Framery O VCR Troubleshooting instructions info frameryacoustics com 23 ...

Page 24: ...ution Adjust the position of the wall cover panels 1 Remove the body cover that does not fit and the body cover next to it 2 Unscrew the 4x30 screws 8 pcs and remove the wall cover panel 24 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 25: ...er panel slightly higher or lower and reinstall the cover panel Note Make sure that the cover panel is positioned straight 4 Install the body covers Framery O VCR Troubleshooting instructions info frameryacoustics com 25 ...

Page 26: ...on Check that the power cord is connected to a power outlet Cause The power outlet which the pod is connected to does not work Solution If needed connect the power cord of the pod to another power outlet Cause One or more electrical connections are disconnected Solution Check all the electrical connections inside the table 1 Disconnect the power cord 26 Framery O VCR Troubleshooting instructions i...

Page 27: ...ountersunk M6x25 screws 2 pcs from the table bottom board and open the table bottom board 3 Check that all the electrical connections are secure Framery O VCR Troubleshooting instructions info frameryacoustics com 27 ...

Page 28: ...table bottom board with countersunk M6x25 screws 2 pcs Note Make sure that the cords are not between the table boards 5 Connect the power cord 28 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 29: ...ion Check that the connection between the power cord and AC extension cord is secure power cord installed from the floor 1 Disconnect the power cord 2 Remove the wall body cover from the techwall Framery O VCR Troubleshooting instructions info frameryacoustics com 29 ...

Page 30: ...3 Remove the bottom body cover 4 Unscrew the 4x30 screws 8 pcs and remove the wall cover panel 30 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 31: ...t the connection between the power cord and AC extension cord is secure 6 Install the removed parts in reverse order 7 Connect the power cord Framery O VCR Troubleshooting instructions info frameryacoustics com 31 ...

Page 32: ...between the power cord and AC extension cord is secure power cord installed from the roof 1 Disconnect the power cord 2 Remove the wall body cover from the techwall 32 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 33: ...3 Remove the roof body cover 4 Unscrew the 4x30 screws 8 pcs and remove the wall cover panel Framery O VCR Troubleshooting instructions info frameryacoustics com 33 ...

Page 34: ...t the connection between the power cord and AC extension cord is secure 6 Install the removed parts in reverse order 7 Connect the power cord 34 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 35: ... Solution Reset the fuse 1 Disconnect the power cord 2 Remove countersunk M6x25 screws 2 pcs from the table bottom board and open the table bottom board Framery O VCR Troubleshooting instructions info frameryacoustics com 35 ...

Page 36: ...3 Turn the ON OFF switch of the power unit in the I position 4 Fasten the table bottom board with countersunk M6x25 screws 2 pcs 36 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 37: ...ower outlet is most likely overloading the circuit and causing the fuse to trip Disconnect the faulty device from the power outlet 4 2 The power outlet does not work Condition The fans and lights work normally There is no electricity in the power outlet in the table Framery O VCR Troubleshooting instructions info frameryacoustics com 37 ...

Page 38: ...tion Check that the power outlet cord is connected 1 Disconnect the power cord 2 Remove countersunk M6x25 screws 2 pcs from the table bottom board and open the table bottom board 38 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 39: ... that the power outlet cord is securely connected to the AC splitter 4 Fasten the table bottom board with countersunk M6x25 screws 2 pcs Framery O VCR Troubleshooting instructions info frameryacoustics com 39 ...

Page 40: ...5 Connect the power cord 40 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 41: ...switch on when a person enters the pod but the power outlet in the table works Cause One or more electrical connections are disconnected Solution Check all the electrical connections inside the table 1 Disconnect the power cord Framery O VCR Troubleshooting instructions info frameryacoustics com 41 ...

Page 42: ...ountersunk M6x25 screws 2 pcs from the table bottom board and open the table bottom board 3 Check that all the electrical connections are secure 42 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 43: ...table bottom board with countersunk M6x25 screws 2 pcs Note Make sure that the cords are not between the table boards 5 Connect the power cord Framery O VCR Troubleshooting instructions info frameryacoustics com 43 ...

Page 44: ...disconnected Solution Check that the connection between the roof module DC cord and wall module DC cord is secure 1 Disconnect the power cord 2 Remove the wall body cover from the techwall 44 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 45: ...3 Remove the roof body cover 4 Unscrew the 4x30 screws 8 pcs and remove the wall cover panel Framery O VCR Troubleshooting instructions info frameryacoustics com 45 ...

Page 46: ...or is broken To determine if the motion detector is broken disconnect the power cord of the pod and reconnect it If the fans and light switch on normally and go off after 8 minutes but do not switch on when a person enters the pod the motion detector is broken Solution Contact Framery support for a replacement part 46 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 47: ...reen LED in the PWR IN connector of the control unit is not lit the converter that supplies power to the control unit is broken Solution Contact Framery support for a replacement part 5 2 The ceiling light does not switch on Condition The ceiling light does not work The fans and the power outlet in the table work normally Cause The light s electrical connections are disconnected Solution Check tha...

Page 48: ...om the ceiling Note Be careful when removing the light The metal springs holding the light in place may break 3 Check that the connectors are securely connected 48 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 49: ...4 Push the light back into the ceiling 5 Connect the power cord Framery O VCR Troubleshooting instructions info frameryacoustics com 49 ...

Page 50: ...tion Check that the light cord is connected to the control unit 1 Disconnect the power cord 2 Remove countersunk M6x25 screws 2 pcs from the table bottom board and open the table bottom board 50 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 51: ...o the LED 1 connector of the control unit 4 Fasten the table bottom board with countersunk M6x25 screws 2 pcs Note Make sure that the cords are not between the table boards Framery O VCR Troubleshooting instructions info frameryacoustics com 51 ...

Page 52: ...ken or disconnected Solution Contact Framery support for a replacement part 5 3 The display light does not switch on Condition The display light does not work The fans ceiling light and power outlet in the table work normally 52 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 53: ...tion Check that the display light cord is connected to the control unit 1 Disconnect the power cord 2 Remove countersunk M6x25 screws 2 pcs from the table bottom board and open the table bottom board Framery O VCR Troubleshooting instructions info frameryacoustics com 53 ...

Page 54: ...ed to the LED 2 connector of the control unit 4 Fasten the table bottom board with countersunk M6x25 screws 2 pcs Note Make sure that the cords are not between the table boards 54 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 55: ...wer cord 5 4 The control panel does not work Cause The control panel cord is disconnected Solution Check that the control panel cord is connected Framery O VCR Troubleshooting instructions info frameryacoustics com 55 ...

Page 56: ...tion Check that the control panel cord is connected to the control unit 1 Disconnect the power cord 2 Remove countersunk M6x25 screws 2 pcs from the table bottom board and open the table bottom board 56 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 57: ...ted to the UI connector of the control unit 4 Fasten the table bottom board with countersunk M6x25 screws 2 pcs Note Make sure that the cords are not between the table boards Framery O VCR Troubleshooting instructions info frameryacoustics com 57 ...

Page 58: ...ly connected If the ceiling light is connected to the connector reserved for the display light LED 2 and vice versa the lights are controlled together Solution Check that the lights are connected to the correct connectors of the control unit 1 Disconnect the power cord 58 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 59: ...he table bottom board 3 Check that the ceiling light cord is connected to the LED 1 connector and the display light cord is connected to the LED 2 connector of the control unit Framery O VCR Troubleshooting instructions info frameryacoustics com 59 ...

Page 60: ... Note Make sure that the cords are not between the table boards 5 Connect the power cord 5 6 One or both fans do not work Condition The light and power outlet work normally The fans are not running 60 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 61: ...are disconnected Solution Check that the fan module s electrical connections are secure 1 Disconnect the power cord 2 Remove the 3 5x16 screws 4 pcs and take out the fan module Framery O VCR Troubleshooting instructions info frameryacoustics com 61 ...

Page 62: ...3 Check that the fan DC cord and the DC extension cord are securely connected 4 Reinstall the fan module 62 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 63: ...rd Cause The fan cord is not connected to the control unit Solution Check that the fan cord is connected to the control unit 1 Disconnect the power cord Framery O VCR Troubleshooting instructions info frameryacoustics com 63 ...

Page 64: ... screws 2 pcs from the table bottom board and open the table bottom board 3 Check that the fan cord is connected to the FAN 1 connector of the control unit 64 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 65: ...t the cords are not between the table boards 5 Connect the power cord Cause One of the wires of the roof module or wall module DC cord is broken or disconnected Solution Contact Framery support for a replacement part Framery O VCR Troubleshooting instructions info frameryacoustics com 65 ...

Page 66: ...abnormal sound Cause There is something touching the fan blades Solution Check that there is nothing touching the fan blades 1 Disconnect the power cord 2 Remove the 3 5x16 screws 4 pcs from the fan module 66 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 67: ... Take out the fan module and disconnect the fan DC cord 4 Check that there is nothing touching the blades 5 Connect the fan DC cord Framery O VCR Troubleshooting instructions info frameryacoustics com 67 ...

Page 68: ...pe with a hard surface may increase the fan noise by reflecting sound Solution If needed move the pod to a more suitable location Cause The fan speed is set to 100 By default the fan speed is set to the maximum speed Reducing the fan speed reduces the noise the fans produce 68 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 69: ...he fan speed to under 80 when occupied is not recommended It is at your own risk to set the fan speed to under 80 when occupied Solution Reduce the fan speed 1 Disconnect the power cord 2 Remove the countersunk M6x25 screws 2 pcs from the table bottom board and open the table bottom board Framery O VCR Troubleshooting instructions info frameryacoustics com 69 ...

Page 70: ...off after 8 minutes of no activity in each of the settings Note Reducing the fan speed decreases the rate of air flow inside the pod Adjusting the fan speed to under 80 when occupied is not recommended It is at your own risk to set the fan speed to under 80 when occupied 70 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 71: ... 5 80 25 80 50 6 100 0 92 50 7 80 0 92 50 8 80 0 100 50 9 100 0 100 50 A 60 0 92 50 B 70 0 92 50 C 50 25 92 50 D 60 25 92 50 E 70 25 92 50 F 100 25 92 50 4 Fasten the table bottom board with countersunk M6x25 screws 2 pcs Note Make sure that the cords are not between the table boards Framery O VCR Troubleshooting instructions info frameryacoustics com 71 ...

Page 72: ...rd 5 8 The air inside the pod does not feel fresh Cause The ventilation channels are dirty Solution Clean the ventilation channels with a vacuum cleaner 72 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 73: ...olution Check that the fan module s electrical connections are secure 1 Disconnect the power cord 2 Remove the 3 5x16 screws 4 pcs and take out the fan module Framery O VCR Troubleshooting instructions info frameryacoustics com 73 ...

Page 74: ...3 Check that the fan DC cord and the DC extension cord are securely connected 4 Reinstall the fan module 74 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 75: ...5 Connect the power cord Solution Check that the fan cord is connected to the control unit 1 Disconnect the power cord Framery O VCR Troubleshooting instructions info frameryacoustics com 75 ...

Page 76: ... screws 2 pcs from the table bottom board and open the table bottom board 3 Check that the fan cord is connected to the FAN 1 connector of the control unit 76 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 77: ...table bottom board with countersunk M6x25 screws 2 pcs Note Make sure that the cords are not between the table boards 5 Connect the power cord Framery O VCR Troubleshooting instructions info frameryacoustics com 77 ...

Page 78: ...f the motion detector Solution Adjust the settings of the motion detector 1 Disconnect the power cord 2 Remove the countersunk M6x25 screws 2 pcs from the table bottom board and open the table bottom board 78 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 79: ...off after 8 minutes of no activity in each of the settings Note Reducing the fan speed decreases the rate of air flow inside the pod Adjusting the fan speed to under 80 when occupied is not recommended It is at your own risk to set the fan speed to under 80 when occupied Framery O VCR Troubleshooting instructions info frameryacoustics com 79 ...

Page 80: ... 5 80 25 80 50 6 100 0 92 50 7 80 0 92 50 8 80 0 100 50 9 100 0 100 50 A 60 0 92 50 B 70 0 92 50 C 50 25 92 50 D 60 25 92 50 E 70 25 92 50 F 100 25 92 50 4 Fasten the table bottom board with countersunk M6x25 screws 2 pcs Note Make sure that the cords are not between the table boards 80 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 81: ...ocated under a heating duct or in direct sunlight the temperature inside the pod might rise If there is not enough space around the pod air does not circulate sufficiently Figure 2 Operating space measurements Framery O VCR Troubleshooting instructions info frameryacoustics com 81 ...

Page 82: ...or handle is loose Cause The screws are not properly tightened Solution Reinstall the handle 1 Loosen the set screw on the inside handle 2 Remove the M5x32 screws 82 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 83: ...he set screw on the outside handle 5 Adjust the spindle at least 5 mm to find a new spot for the set screw to pierce the spindle Note Do not turn or rotate the spindle in any way because it can only be pierced on one side Framery O VCR Troubleshooting instructions info frameryacoustics com 83 ...

Page 84: ...ndle Note In the final position the head of the set screw is level with the handle surface 7 Do either of the following Replace the M5x32 screws with new ones Note Make sure that the new screws have Loctite Add Loctite to the existing screws 84 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 85: ...e lock latch gets stuck 9 Tighten the set screw on the inside handle The resistance increases steadily until the screw pierces the spindle Note In the final position the head of the set screw is level with the handle surface Framery O VCR Troubleshooting instructions info frameryacoustics com 85 ...

Page 86: ...s are overtightened Solution Reinstall the handle 1 Loosen the set screw on the inside handle 2 Remove the M5x32 screws 3 Remove the inside handle and the outside handle with the spindle attached to it 86 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 87: ...st the spindle at least 5 mm to find a new spot for the set screw to pierce the spindle Note Do not turn or rotate the spindle in any way because it can only be pierced on one side Framery O VCR Troubleshooting instructions info frameryacoustics com 87 ...

Page 88: ...ndle Note In the final position the head of the set screw is level with the handle surface 7 Do either of the following Replace the M5x32 screws with new ones Note Make sure that the new screws have Loctite Add Loctite to the existing screws 88 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 89: ...handle The resistance increases steadily until the screw pierces the spindle Note In the final position the head of the set screw is level with the handle surface 6 3 The lock latch is stiff or gets stuck Condition The lock latch gets stuck in either the extended or retracted position Framery O VCR Troubleshooting instructions info frameryacoustics com 89 ...

Page 90: ...ened Solution Reinstall the handle 1 Loosen the set screw on the inside handle 2 Remove the M5x32 screws 3 Remove the inside handle and the outside handle with the spindle attached to it 90 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 91: ...st the spindle at least 5 mm to find a new spot for the set screw to pierce the spindle Note Do not turn or rotate the spindle in any way because it can only be pierced on one side Framery O VCR Troubleshooting instructions info frameryacoustics com 91 ...

Page 92: ...ndle Note In the final position the head of the set screw is level with the handle surface 7 Do either of the following Replace the M5x32 screws with new ones Note Make sure that the new screws have Loctite Add Loctite to the existing screws 92 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 93: ...e lock latch gets stuck 9 Tighten the set screw on the inside handle The resistance increases steadily until the screw pierces the spindle Note In the final position the head of the set screw is level with the handle surface Framery O VCR Troubleshooting instructions info frameryacoustics com 93 ...

Page 94: ...94 Framery O VCR Troubleshooting instructions info frameryacoustics com ...

Page 95: ......

Page 96: ...Framery O VCR Troubleshooting instructions Patamäenkatu 7 33900 Tampere FINLAND VAT FI 23527139 ...