IN
– VA10
- 31 -
© Future Products Group
Cabinet Performance
VISAIR CABINETS
-
SPECIFICATIONS
Refrigerated
Section
Performance
Operating Temperature
Average Internal Humidity
Climatic Class 3 Test Conditions
+2° to +4°C
N/A
25°C Ambient with 60% RH
Controller Settings
VISAIR CABINETS
-
SPECIFICATIONS
Dixell XR40CX Settings
Parameter
IN-VA10
Units / Range
Set Point
Set
-4
degC
Differential
Hy
4
degC
Fourth Probe Presence
P4P
Y
N,Y
Fourth Probe Calibration
O4
-4
degC
Anti Short Cycle Delay
AC
0
Min
Comp On Time - Faulty Probe
Con
4
Min
Comp Off Time - Faulty Probe
CoF
6
Min
Probe Displayed
Lod
P4
P1, P2, P3, P4
Defrost Terminate Temp
dtE
3
degC
Interval Between Defrosts
IdF
2
Hrs
Display During Defrost
dFd
DEF
rt, it, Set, DEF
Probe For High Discharge Temp Alarm
AP2
nP
nP, P1, P2, P3, P4
Digital Input Polarity
i1P
oP
cL, oP
Digital Input Configuration
i1F
bAL
EAL, bAL, PAL, dor, dEF, AUS, Htr, ES
Digital Input Alarm Delay
did
1
Min
Number Of Activations Of Pressure switch
Nps
1
0 - 15
Mains Lead
VISAIR CABINETS
-
SPECIFICATIONS
Lead
Replacement
If the supply cord is damaged, it must be replaced by a special cord or
assembly available from the manufacturer or its service agent, FPG part
number 13237. The mains lead must ONLY be replaced by a qualified service
person.
Summary of Contents for Visair IN-VA10-A004
Page 1: ...Open Front Food Drinks Cabinet AS NZS ...
Page 35: ...IN VA10 35 Future Products Group MECHANICAL DRAWINGS Inline Visair IN VA10 A004 ...
Page 36: ...Part No 25553 Rev J November 2017 36 Visair Refrigerated Cabinets Inline Visair IN VA10 A005 ...
Page 37: ...IN VA10 37 Future Products Group ...
Page 38: ...Part No 25553 Rev J November 2017 38 Visair Refrigerated Cabinets ...