Visair Refrigerated Cabinets
Refrigeration Equipment
VISAIR CABINETS
-
SERVICING
Caution
DO NOT attempt to service the refrigeration equipment without isolating
the cabinet from the mains supply.
Refrigeration
Equipment
The compressor,
condenser fan and
condensate disposal
system are mounted in
the base of the
cabinet, behind the
condenser radiator.
Unscrew the lower
back panel to gain
access.
Compressor
The scroll type compressor is
hermetically sealed.
It is fitted with a dryer, an auto reset
Low Pressure and a manual reset
High Pressure switch.
Two access ports are provided for
pressure monitoring and charging with
refrigerant.
Condensate
Disposal
The condensate
disposal system
consists of a water tray,
a water level detector
and a boil-off element
with an over
temperature cut-out.
If the element fails, it
may be replaced by
springing it from the
mounting bracket. Cut
and splice the leads
and protect with heat-
shrink sleeves.
Continued on next page