background image

IMPORTANT!

Initial Operation

This electronic caliper comes supplied with a 
battery and is instantly operational. However, 
we suggest you read this manual prior to using 
your instrument.

Internal Jaws

Locking Screw

Display

 External Jaws

Function Buttons

Battery Cover

Beam

Depth Measurement Rod

Thumbroll

On/Off:   

Press  <on>  button  once  to  turn  on. 

Press button an additional time to turn off.

Zero Setting: 

Press <zero> function button.

Change Measuring Standard: 

Press  <mm/in/F>  function  button  to  toggle 
between mm, in or fractions.

Absolute/Incremental: 

Press <abs> button, to 

return to zero function press button again.

Once Display begins flashing:

• 

Slide off the battery cover and rubber gasket, 

then remove the battery by gently tapping the 

instrument in your hand. (Never try to force 

or pry the battery out). Insert the new battery 

with the positive pole "+" facing upwards and 

replace the gasket and cover.

• 

Please dispose of used batteries at a proper 

collection center.

Clean  the  caliper  with  a  soft  cloth.  DO  NOT 

use any type of solvent.  DO NOT immerse the 

caliper in liquid.

Functions

Battery Replacement

Cleaning

Euro-Caliper IV

54-100-330-1

Step 
Measuring 
Face

In case of water / coolant splash:

The electronic unit for this instrument is water 
resistant.  In  case  of  liquid  splash,  the  display 
may possibly fail. Wipe off the liquid, be sure the 
liquid between the slider and beam is completely 
dried. Then reset the instrument.