F8X14 Series User Manual
Power adapter and communication cable connection chart as following:
2.4 Power
The power range of the IP MODEM is DC 5~35V. When we use other power, we should make
sure that the power can supply power above 4W.
We recommend user to use the standard DC 12V/0.5A power adaptor.
2.5 Indicator Lights Introduction
The IP MODEM provides three indicator lights: “Power”, “ACT”, “Online”.
Indicator
Light
State
Introduction
Power
ON
IP MODEM is powered on
OFF
IP MODEM is powered off
ACT
BLINK
Data is communicating
OFF
No data
Online
ON
IP MODEM has logged on network
OFF
IP MODEM hasn’t logged on network
ZigBee
ON
ZigBee Transport data
OFF
No data
Communication Interface: RS232
Communication Interface: RS485
F8X14 Terminal
Block Interface
User Device
(DB9M)
User Device
1
2
3
4
5
6
7
8
9
10
11
12
RX
GND
TX
A
B
IO1
IO2
IO3
IO4
PWR
GND
IO5
+ Anode
- Cathode
A
B
F8X14 Terminal
Block Interface
1
2
3
4
5
6
7
8
9
10
11
12
RX
GND
TX
A
B
IO1
IO2
IO3
IO4
PWR
GND
IO5
1
2
3
4
5
6
7
8
9
GND
TX
RX
+ Anode
- Cathode
RX
Summary of Contents for F8 14 Series