NetIron(config)# show version
HW:NetIron MLX Router
Backplane (Serial #: Not Exist, Part #: Not Exist)
NI-MLX-SFM Switch Fabric Module 1 (Serial #: PR23050277, Part #: 31523-100A)
NI-MLX-SFM Switch Fabric Module 2 (Serial #: PR23050291, Part #: 31523-100A)
NI-MLX-SFM Switch Fabric Module 3 (Serial #: PR23050273, Part #: 31523-100A)
NI-MLX-SFM Switch Fabric Module 4 (Serial #: PR23050282, Part #: 31523-100A)
==========================================================================
SL M2: NI-MLX-MR Management Module Active (Serial #: PR23050108, Part #:31524-000A):
Boot : Version 3.0.0T145 Copyright (c) 1996-2003 Foundry Networks, Inc.
Compiled on Sep 2 2005 at 07:29:12 labeled as xmb03000
(336710 bytes) from boot flash
Monitor : Version 3.0.0T145 Copyright (c) 1996-2003 Foundry Networks, Inc.
Compiled on Sep 2 2005 at 07:29:12 labeled as xmb03000
(336710 bytes) from code flash
IronWare : Version 3.0.0T143 Copyright (c) 1996-2003 Foundry Networks, Inc.
Compiled on Sep 2 2005 at 07:27:21 labeled as xmr03000
(6054708 bytes) from Primary
Board ID : 00 MBRIDGE Revision : 13
913 MHz Power PC processor (version 8003/0101) 166 MHz bus
512 KB Boot Flash (AM29LV040B), 32 MB Code Flash (MT28F128J3)
512 MB DRAM
Active Management uptime is 53 minutes 24 seconds
The highlighted lines in the output indicate that the management module currently has MBRIDGE Revision: 13
installed.
Upgrading the MBRIDGE FPGA Image
To upgrade one or more MBRIDGE FPGA images on management modules within a NetIron MLX Series chassis,
perform the following steps:
1.
Place the new MBRIDGE FPGA image on a TFTP server to which the router has access or on a PCMCIA
flash card inserted in slot 1 or 2.
2.
Copy the MBRIDGE FPGA image from the TFTP server or a flash card in slot 1 or 2 to all management
modules. To perform this step, enter one of the following commands at the Privileged EXEC level of the CLI
(for example: NetIron#):
•
copy tftp mbridge
<ip-addr> <image-name>
•
copy slot1 | slot2 mbridge
<image-name>
3.
Verify that the MBRIDGE image(s) have been successfully copied to the management module(s) by entering
the following command at any level of the CLI:
•
show version
Check for the MBRIDGE image version numbers in the output.
Upgrading an FPGA for an Interface Module
Ethernet interface modules contain the following upgradable field-programmable gate array (FPGA) images:
•
PBIF
•
XPP
•
XGMAC (10 Gbps interface modules only)
Packet Over SONET (POS) interface modules contain the following upgradable field-programmable gate array
(FPGA) images:
•
XPPOC
•
PBIFOC