background image

Owner’s Manual

PRINTED IN JAPAN NOVEMBER 2011

546022

RISK OF ELECTRIC SHOCK

           DO NOT OPEN

CAUTION

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,

                DO NOT REMOVE COVER (OR BACK).

WARNING:

              NO USER - SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. 

Avertissement:

To reduce the risk of fire or electric shock, do not expose apparatus 

to rain or moisture.

pour réduire le risque d’incendie ou de choc électrique, ne pas exposer 

cet appareil sous la pluie et l’humidité.

The lightning flash with arrowhead symbol, within an equilat-

eral triangle, is intended to alert the user to the presence of 

uninsulated "dangerous voltage" within the product's enclo-

sure that may be of sufficient magnitude to constitute a risk 

of electric shock to persons.

The  exclamation  point  within  an  equilateral  triangle  is 

intended  to  alert  the  user  to  the  presence  of  important 

operating  and  maintenance  (servicing)  instructions  in  the 

literature accompanying the appliance.   

Read these instructions.

Keep these instructions.

Heed all warnings.

Follow all Instructions.

Do not use this apparatus near water.

Clean only with dry cloth.

Do not block any ventilation openings. Install in accordance with 

the manufacturer’s instructions.

Do  not  install  near  any  heat  sources  such  as  radiators,  heat 

registers,  stoves,  or  other  apparatus  (including  amplifiers)  that 

produce heat.

Do not defeat the safety purpose of the polarized or grounding - 

type plug. A polarized plug has two blades with one wider than the 

other. A grounding type plug has two blades and a third grounding 

prong.  The  wide  blade  or  the  third  prong  are  provided  for  your 

safety. If the provided plug does not fit into your outlet, consult an 

electrician for replacement of the obsolete outlet.

Protect the power cord from being walked on or pinched particularly 

at plugs, convenience receptacles, and the point where they exit 

from the apparatus.

Only use attachments/accessories specified by the manufacturer.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

Unplug this apparatus during lightning storms or when unused for 

long periods of time.

Refer  all  servicing  to  qualified  service  personnel.  Servicing  is 

required when the apparatus has been damaged in any way, such 

as power-supply cord or plug is damaged, liquid has been spilled or 

objects  have  fallen  into  the  apparatus,  the  apparatus  has  been 

exposed  to  rain  or  moisture,  does  not  operate  normally,  or  has 

been dropped. 

The apparatus shall be used in an open area.

Cet  appareil doit être utilisé dans un endroit a aire ouverte.

Apparatus shall not be exposed to dripping or splashing and that no 

objects filled with liquids, such as vases, shall be placed on appara-

tus.

L’appareil ne doit pas êclaboussures et aucun objet ne contenant 

de liquide, tel qu’un vase, ne doit être placé sur lobjet.

Mains  plug  is  used  as  disconnect  device.  It  shall  remain  readily 

operable  and  should  not  be  obstructed  during  intended  use.  To 

completely disconnect the apparatus from supply mains, the mains 

plug of the apparatus shall be disconnected from the mains socket 

outlet completely.

La prise du secteur et utilisé pou déconnecter le système. La prise 

du secteur ne doit pas être obstruée ou doit être facilement acces-

sible pendant son utilisation. Pour être complètement déconnecté 

de l’alimentation d’entrée, la prise doit être débranchée du secteur.

13.

14.

15.

16.

17.

Use only with the cart, stand, tripod, bracket, or 

table specified by the manufacturer, or sold with 

the apparatus. When a cart is used, use caution 

when moving the cart/apparatus combination to 

avoid injury from tip-over.

IMPORTANT SAFETY INSTRUCTIONS

+ terminal (RED MARKING)

ø145

ø146

ø190

11

8

73.4 (86.2)

6
18

32

41.4

ø174

8-ø6 hole

8-ø11 counterbored hole

Impedance characteristic

Main Features

FE163En-S is a direct line from FE163 and is an over-damping speaker unit that has been developed based on all the skills that 

Fostex cultivated in the past. Retaining the FE series' middle-high range bright and forceful sound characteristics, a fulfilled 

low-mid range and a smooth frequency response up to a higher range are realized. A light-weight and easy-to-drive diaphragm 

is driven by a powerful magnetic circuit. This allows to realize a linear response from low to high input level, a superb acoustic 

field position and fine as well as powerful high-definition sound reproduction.

• Corrugation type light-weight fiber edge

While steadily holding the ES cone paper, a corrugation type fiber edge is employed to realize a higher compliance and to improve the 

linearity. On FE163En-S, by changing the shape of edge inner/outer circumstances and peaks/troughs intermediate part, an edge-

specific resonance has been diverged and lightened for a better response from a low to high input level. Also a thick low-mid sound 

even with an over-dampling characteristic as well as a clear and flat mid-high frequency response have been achieved.

• Three-point adhesion / pocket-neck damper

A three-point adhesion which binds the cone paper, spider and voice coil bobbin at the same line is employed to enhance the strength 

of the inside rim of the cone paper for stable high frequency characteristics. Employing a pocket-neck damper which puts a pocket 

shape at the damper neck section allows a three-point adhesion even with the use of a junction cable to the voice coil and reduces a 

transmission loss from the voice coil to the input terminal.

• Low-distortion large ferrite magnetic circuit

A 145 mm diameter large ferrite magnet is employed for the magnetic circuit to ensure a substantial magnetic flux density. A nickel 

plating process is applied onto the magnetic circuit metal part surface finishing. With a placement of copper ring to the inner circum-

stance of the magnet, a current distortion is lessened to realize a low distortion of the drive system.

• Highly-rigid aluminum die-cast frame

A high-rigid aluminum die-cast frame which securely holds a low-distortion large magnetic circuit and does not transmit an unneces-

sary vibration to the cone paper is employed.

• Gold-coated 205 Faston receptacle terminal / High definition OFC (Oxygen Free Copper) interconnection material

Less junction-loss gold-coated Faston receptacle terminals are employed to avoid a sound degradation as much as possible. Employing 

high definition OFC cables lessen a transmission loss from the speaker input terminals to the speaker unit.

Dimensions / Specifications / Frequency Response

    

Accessories

- Wood screws x 8 pcs.

- Flat washers x 8 pcs.

- Packing x 1 pc.

- OFC internal wiring cable with

  #205 Faston terminal x 2 pcs.

 

16 cm cone type full range

8 Ω

56 Hz

f

0

 ~ 24 kHz

93 dB/W(1m)

80 W

7.0 g

0.23

6.5 cm

1,100 g

3.15 kg

ø151 mm

    Specifications

Type. . . . . . . . . . . . . . . . . . . . . . . . 

Impedance. . . . . . . . . . . . . . . . . . .  

Lowest resonance frequency (f

0

). . 

Frequency response. . . . . . . . . . . . 

Output sound pressure level. . . . . .

Input (Music). . . . . . . . . . . . . . . . . .

m

0

. . . . . . . . . . . . . . . . . . . . . . . . . .

Q

0

. . . . . . . . . . . . . . . . . . . . . . . . . .

Equivalent diaphragm radius. . . . . 

Magnet weight. . . . . . . . . . . . . . . .

Net weight. . . . . . . . . . . . . . . . . . . .

Baffle hole diameter. . . . . . . . . . . .

    

Frequency Response

Reviews: