     WWA-02AA 

Wireless Water & Freeze /            

      Temperature Alarm,

 

User Manual

 

         

      

        

 

 

 

 

 

 

1080 Centre Rd, Suite C 
Auburn Hills, MI 48326 

www.fortrezz.com

 

 

Phone: (248) 481-7092 

[email protected]

         

  Made in USA            

 

Thank you for purchasing this Wireless Water & Freeze / Temperature Alarm. This product will provide you with peace of mind and the 
protection you expect. Leaking pipes, corroded water heaters, fixtures in bathrooms and laundry rooms, refrigerator drip pans, etc. can 
all  cause  water  damage.    The  WWA-02AA  is  a  Z-Wave

TM 

enabled  device  that  will  send  a  water  alert  on  your  Z-Wave

TM 

network.  

Devices performing other functions and from other manufacturers can also be part of your 

Z-Wave

TM 

network and can act as repeaters 

to extend your network range

.

 

 
Functionality: 

The WWA-02AA alarms when water is detected and will also provide a Z-Wave

TM

 alarm signal when the temperature drops below a low 

temperature  setpoint  or  rises  above  a  high  temperature  setpoint.   

The  WWA-02AA  functionality  is  based  on  wireless  (RF) 

transmissions.      Any  wireless  transmission  can  be  subject  to  RF  interference  and,  although  unlikely,  this  interference  may 
cause  the  unit  to  not  operate  as  intended.  The  WWA-02AA  must  not  be  used  in  life  support  and/or  safety  applications.  
Information provided in this manual is for your convenience and may be superseded by updates.  The specifications and this 
manual are subject to change without notice. It is your responsibility to ensure that the WWA-02AA meets your specifications.  

 

 
Specifications: 

Power:  

Two AA alkaline batteries 

Battery Life: 

Calculated to be 1 to 2 years   with no alarms and default Z-Wave

TM

 network settings  

Frequency Range: 

908.4MHz (US);   868.4MHz (EU) 

Distance Range: 

Max 100ft line of sight in unobstructed environment 

Size (LxWxD) and Weight: 

3" (76 mm) x 2.1" (53mm) x 1.1" (30mm) 

Product Weight: 

0.24 lb (109 g) 

Operating Temperature: 

-10ºC (14F) to +70ºC (158F) 

Reported Temperature: 

Reported temperature is at the unit and has a +/- 2 degC accuracy 

System Requirement:  

Any Z-Wave

TM

 enabled network and controller.

 

 
Using the WWA-02AA in a Z-Wave

TM

 Network

 Program Switch for Inclusion or Exclusion   

 

The switch is used for including or excluding the WWA-02AA in a Z-Wave

TM

 network.   

 
Refer to your controller’s User Manual for specific details on network inclusion, exclusion, and association. 

          

 

Inclusion

 in (adding to) a network: 1) Set up the inclusion mode at the controller; 2) Briefly press the switch once and the controller will 

indicate the unit has been included in the network.  Also, the LED will blink when the inclusion completes.  

Inclusion and exclusion are 

always done at normal transmit power mode. 

 

Exclusion

 from (removing from) a network: 1) Set up the exclusion  mode at the controller; 2) Press and hold the switch for approx. 2 

seconds until the controller indicates the unit has been removed from the network.  The LED will blink when the exclusion completes. 

 

Associations:  

Once in a network, a controller can be used to associate the WWA-02AA with other devices in the Z-Wave

TM

 network, 

such as a light or another remote audible alarm. 

Refer to your controller’s documentation on how to associate WWA-02AA with another 

device  in  your  network.

  The  WWA-02AA  supports  three  association  groups  with  a  maximum  of  5  devices  in  each  group.    Basic  Set 

commands are sent at 30-minute intervals to the associated groups while alarms are active.   

  A Basic Set Command is sent to the associated nodes, if any, assigned to Group1 to indicate that EITHER a Water Alarm OR 

Heat Alarm (under or over temperature) is active. 

  A Basic Set Command with value = 0xFF is sent to the associated nodes, if any, assigned to Group2 to indicate that a Water 

Alarm is active.  When the water alarm is cleared by drying the contacts, one additional report with value = 0x00 is sent.  

 

A Basic Set Command is sent to the associated nodes, if any, assigned to Group3 to indicate that a Temperature Alarm (over or 

under temperature) is active. When the temperature alarm is cleared due to temperature change, one additional report with value = 
0x00 is sent.

  

 
Node Info / Keep-Alive:

  While not in a network, the WWA-02AA will send the Z-Wave

TM

 Node information frame when the switch is 

briefly pressed.  This is primarily used for inclusion as described above.  The node information frame will also be sent  while in network 
when the switch is pressed and held for 2 seconds.  In either case, the WWA-

02AA will ‘stay awake’ for approximately 30 seconds after 

this to allow time for configuration commands from the controller.  Refer to Status indications below for LED feedback. 
 

Wakeup Notification:

  The WWA-02AA will wakeup and send a notification every 4 hours (default) to allow a controller to query and 

update the status of the unit.   A brief switch press while in network will also cause the WWA-02AA to wakeup and send a notification.  
The device stays awake for 5 seconds during this time or longer if communicating with the controller. 

Summary of Contents for WWA-02AA

Page 1: ...ode at the controller 2 Briefly press the switch once and the controller will indicate the unit has been included in the network Also the LED will blink when the inclusion completes Inclusion and exclusion are always done at normal transmit power mode Exclusion from removing from a network 1 Set up the exclusion mode at the controller 2 Press and hold the switch for approx 2 seconds until the cont...

Page 2: ...ateway controllers you can receive an email or cell phone text message when an alarm is activated Depending on your specific controller s capabilities you will be able to remotely check the status of any WWA 02AA in your network Testing the WWA 02AA Moisten a paper towel and place over both of the small metal pads on the water sensor until you observe two quick LED blinks The water alarm indicatio...

Page 3: ...circuitry that is not directly associated with the radio transmitter the device shall also have to comply with ICES 003 Class A or B as appropriate except for ICEC 003 labeling requirements The test data obtained for the ICES 003 tests shall be kept by the manufacturer or importer whose name appears on the equipment label and made available to Industry Canada on request for as long as the model is...

Page 4: ... heat alarm state When temperature alarm is no longer active sends Basic Set with Value 0x00 to association nodes as above and or sends Alarm Command Class Heat Report Unknown Event 0xFE with Alarm Level 0x00 BATTERY STATUS Battery level percentage estimated based on number of Wakeup1 s see below since battery insertion In addition battery voltage readings can trip the low battery state Low batter...

Reviews: